Alfredo, I have developed non-zc system where two processes working with one network interface independently using pfring_* API, and I want to migrate to pfring-zc. But if one process opens interface, other process can't open same device with error "Device or resource busy".
Can I use one network interface independently in two processes in zc mode? Ilya. 2014-08-31 18:36 GMT+04:00 Alfredo Cardigliano <[email protected]>: > Hi Ilya > if a process leaves a queue/cluster in an inconsistent state (i.e. it does > not call pfring_zc_ipc_detach_*), > the queue cannot be resumed. Please note that this should be an exception and > handled as such (restarting the cluster) > > Alfredo > > On 31 Aug 2014, at 16:28, Ilya Gavrilov <[email protected]> wrote: > >> Hello, >> >> If process that uses pfring_zc_ipc_attach_queue (like zbounce_ipc) >> crashed (for example with 9 signal or OOM killer) and doesn't call >> pfring_zc_ipc_attach_queue at exit, next call >> pfring_zc_ipc_attach_queue in new process with same parameters will be >> failed. >> >> I don't want to restart process which creates zc_ipc_queue, >> is there a way to reopen zc_ipc_queue after crash? >> >> Ilya. >> _______________________________________________ >> Ntop-misc mailing list >> [email protected] >> http://listgateway.unipi.it/mailman/listinfo/ntop-misc > > _______________________________________________ > Ntop-misc mailing list > [email protected] > http://listgateway.unipi.it/mailman/listinfo/ntop-misc _______________________________________________ Ntop-misc mailing list [email protected] http://listgateway.unipi.it/mailman/listinfo/ntop-misc