Re: [Histonet] Histonet Digest, Vol 188, Issue 14

2019-07-18 Thread Virginia McIlhargy via Histonet
Works for me!


Virginia McIlhargy

466 Old Hook Rd Suite 1 Emerson, NJ 07630
p: 201-483-2687
d: 
f: 201-383-9700

http://www.bergenmed.comĀ 


This message (and any associated files) is intended only for the use of the 
individual or entity to which it is addressed and may contain information that 
is confidential. If you are not the intended recipient you are hereby notified 
that any dissemination, copying or distribution of this message, or files 
associated with this message, is strictly prohibited. If you have received this 
message in error, please notify us immediately by replying to the message and 
deleting it from your computer.


-Original Message-
From: histonet-requ...@lists.utsouthwestern.edu 
[mailto:histonet-requ...@lists.utsouthwestern.edu] 
Sent: Thursday, July 18, 2019 1:00 PM
To: histonet@lists.utsouthwestern.edu
Subject: Histonet Digest, Vol 188, Issue 14

Send Histonet mailing list submissions to
histonet@lists.utsouthwestern.edu

To subscribe or unsubscribe via the World Wide Web, visit
http://lists.utsouthwestern.edu/mailman/listinfo/histonet
or, via email, send a message with subject or body 'help' to
histonet-requ...@lists.utsouthwestern.edu

You can reach the person managing the list at
histonet-ow...@lists.utsouthwestern.edu

When replying, please edit your Subject line so it is more specific than "Re: 
Contents of Histonet digest..."

___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet


[Histonet] Tissue Adherence Issue

2019-07-18 Thread Dorothy Hu via Histonet
>
>  2. Tissue Adherence Issue (Knutson, Deanne)
>

Hello,

I think your testing tissue might be over or under fixed in formaldehyde
fixative?
You didn't tell what kind of tissue though. We deal with bone tissue which
needs extensively bake (at 37, 46 degree over night and 58 one hour) and
carefully handled. Superfrost Plus slides are used. Especially gentle heat
for heat induced antigen retrieval. Try to use enzyme antigen retrieval as
possible.
Best luck.

Dorothy Hu



> Message: 2
> Date: Wed, 17 Jul 2019 09:21:49 -0500
> From: "Knutson, Deanne" 
> To: "'histonet@lists.utsouthwestern.edu'"
> 
> Subject: [Histonet] Tissue Adherence Issue
> Message-ID:
> <
> 1e0e2b14c709174b8ac2be0ae7f768330159b5756...@exchange2k7.staprimecare.org>
>
> Content-Type: text/plain; charset="us-ascii"
>
> Fellow Histonetters -
>
> I would appreciate your feedback on an intermittent issue that has shown
> up in our lab.
> All of a sudden, we are having difficulty with tissue specimens falling
> off of our slides on the IHC stains and special stains sporadically.
> About a year ago, we switched instruments on the IHC bench from the Leica
> BOND to the ROCHE ULTRA, and we use the Ventana NexES special stainer.
> No adherence issues with all of the validation slides that were run.
> We have tried various types of slides recently as well, and the issue
> still prevails.
>
> Would any of you mind telling me your slide workflow - type of slide used,
> gelatin or not used in flotation bath, how long slides are cooked, etc
> for your IHC slides, for your special stains slides, and even for your H&E
> slides.
> I would welcome your suggestions and feedback.
>
> Thank you so much!!!
>
> Deanne Knutson
> Supervisor
> Anatomic Pathology
>
>  [X]
>  "Let All Be Received as Christ."
>
>
>
___
Histonet mailing list
Histonet@lists.utsouthwestern.edu