Re: Monitor Configuration Records

2008-01-04 Thread barton

Yes, but we try and hide the bullet.



Dixon, Patricia A wrote:

Can the Domain 1 records be individually disabled with ESAMON?  


-Original Message-
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of barton
Sent: Friday, January 04, 2008 10:01 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Monitor Configuration Records

Another possibility, if they use ESAMON or ESALPS to collect the data,
the user has the 
option of disabling those records. Give a user a gun and a bullet and

they will find a foot.




Dixon, Patricia A wrote:



Hi,

If I see a 1/11 which tells me I have a complete set of configuration
records, why am I not seeing the 1/6?  I am also seeing other
configuration records too, such as the 1/15 (user) and 1/8 (paging) in
the monitor data I'm analyzing but no 1/6.  


Thanks,
Pat 


-Original Message-
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]


On


Behalf Of Rob van der Heij
Sent: Friday, January 04, 2008 8:44 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Monitor Configuration Records

On Jan 4, 2008 2:10 PM, Dixon, Patricia A <[EMAIL PROTECTED]>


wrote:




does that mean Domain 1/6 records will not be collected? Is there any


other



reason why 1/6 records would not be created?



Sample configuration area too small

-Rob








Re: Monitor Configuration Records

2008-01-04 Thread Dixon, Patricia A
Can the Domain 1 records be individually disabled with ESAMON?  

-Original Message-
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of barton
Sent: Friday, January 04, 2008 10:01 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Monitor Configuration Records

Another possibility, if they use ESAMON or ESALPS to collect the data,
the user has the 
option of disabling those records. Give a user a gun and a bullet and
they will find a foot.




Dixon, Patricia A wrote:

> Hi,
> 
> If I see a 1/11 which tells me I have a complete set of configuration
> records, why am I not seeing the 1/6?  I am also seeing other
> configuration records too, such as the 1/15 (user) and 1/8 (paging) in
> the monitor data I'm analyzing but no 1/6.  
> 
> Thanks,
> Pat 
> 
> -Original Message-
> From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]
On
> Behalf Of Rob van der Heij
> Sent: Friday, January 04, 2008 8:44 AM
> To: IBMVM@LISTSERV.UARK.EDU
> Subject: Re: Monitor Configuration Records
> 
> On Jan 4, 2008 2:10 PM, Dixon, Patricia A <[EMAIL PROTECTED]>
wrote:
> 
> 
>>does that mean Domain 1/6 records will not be collected? Is there any
> 
> other
> 
>>reason why 1/6 records would not be created?
> 
> 
> Sample configuration area too small
> 
> -Rob
> 
> 


Re: Monitor Configuration Records

2008-01-04 Thread barton
Another possibility, if they use ESAMON or ESALPS to collect the data, the user has the 
option of disabling those records. Give a user a gun and a bullet and they will find a foot.





Dixon, Patricia A wrote:


Hi,

If I see a 1/11 which tells me I have a complete set of configuration
records, why am I not seeing the 1/6?  I am also seeing other
configuration records too, such as the 1/15 (user) and 1/8 (paging) in
the monitor data I'm analyzing but no 1/6.  


Thanks,
Pat 


-Original Message-
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Rob van der Heij
Sent: Friday, January 04, 2008 8:44 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Monitor Configuration Records

On Jan 4, 2008 2:10 PM, Dixon, Patricia A <[EMAIL PROTECTED]> wrote:



does that mean Domain 1/6 records will not be collected? Is there any


other


reason why 1/6 records would not be created?



Sample configuration area too small

-Rob




Re: Monitor Configuration Records

2008-01-04 Thread Rob van der Heij
On Jan 4, 2008 3:31 PM, Dixon, Patricia A <[EMAIL PROTECTED]> wrote:

> If I see a 1/11 which tells me I have a complete set of configuration
> records, why am I not seeing the 1/6?  I am also seeing other
> configuration records too, such as the 1/15 (user) and 1/8 (paging) in
> the monitor data I'm analyzing but no 1/6.

Correct, if you got the end-of-interval then you have seen it all.
And from what I can tell, even when you disable I/O both in sample and
event, you still get configuration records for it.

Rob
-- 
Rob van der Heij
Velocity Software, Inc
http://velocitysoftware.com/


Re: Monitor Configuration Records

2008-01-04 Thread Dixon, Patricia A
Hi,

If I see a 1/11 which tells me I have a complete set of configuration
records, why am I not seeing the 1/6?  I am also seeing other
configuration records too, such as the 1/15 (user) and 1/8 (paging) in
the monitor data I'm analyzing but no 1/6.  

Thanks,
Pat 

-Original Message-
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Rob van der Heij
Sent: Friday, January 04, 2008 8:44 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Monitor Configuration Records

On Jan 4, 2008 2:10 PM, Dixon, Patricia A <[EMAIL PROTECTED]> wrote:

> does that mean Domain 1/6 records will not be collected? Is there any
other
> reason why 1/6 records would not be created?

Sample configuration area too small

-Rob


Re: Monitor Configuration Records

2008-01-04 Thread Rob van der Heij
On Jan 4, 2008 2:10 PM, Dixon, Patricia A <[EMAIL PROTECTED]> wrote:

> does that mean Domain 1/6 records will not be collected? Is there any other
> reason why 1/6 records would not be created?

Sample configuration area too small

-Rob


Monitor Configuration Records

2008-01-04 Thread Dixon, Patricia A
Hello,

 

When setting up the MONITOR profile to collect data, can certain
configuration records (specifically the 1/06 Device) be disabled or be
prevented from being created?  If so, which other configuration records
can be disabled?

 

I checked the CP Commands and Utilities Reference, MONITOR SAMPLE
command ENABLE/DISABLE parameter and see no mention of configuration
records, just the following:

APPLDATA

I/O (ALL, specific devices and classes)

NETWORK

PROCESSOR

STORAGE

USER (ALL, specific userids)

 

However, I do see a note in the manual that the MONITOR and SYSTEM
domains cannot be disabled from data collection.  So if I specified
DISABLE I/O ALL does that mean Domain 1/6 records will not be collected?
Is there any other reason why 1/6 records would not be created?   

 

 

Thank you,  

 

Patricia Dixon

ca

Software Engineer

Tel: +1 703-708-3951

Fax: +1 703-708-3659

[EMAIL PROTECTED]