> Ada yang faham "Barcode Scanner" ? Saya disuruh beli dengan
> spesifikasi seperti ini. Dari list dibawah, hal-hal apa yang penting
> untuk diketahui.
>
> Trims.
>
>
>
> Light Source  : Visible Laser Diode
> Laser Power   : 0.72 mW (peak)
> Depth of Scan Field   : 0 mm – 203 mm (0"-8") for 0.33 mm (13 mll)
> barcodes (at default setting)
> Widht of scan field   : 64 mm (2.5") @ face; 249 mm (9.8") @ 203 mm (8")
> Scan Speed: 72 +/- scan lines per second
> -
>
> Scan pattern  : Single scan line
> Infrared  Activation  : Long range: 0 mm – 279 mm +/- 51 mm ( 0" - 11" +/- 2")
>   : Short range : 0 mm – 102 mm +/- 25 mm (0" - 4" +/- 1")
> Minimum Bar Width : 0.127 mm (5.0 mll)
> Decode Capability : Autodiscriminates all standard barcodes ; for
> other symbologies call Metrologic:
> System Interfaces : RS232, Pckeyboard  wedge, USB
> Print Contrast: 35% minimum reflectance difference
> Number Characters Read: Up to 80 data characters (Maximum number will
> vary based on symbology and density)
> Roll, Pitch, Yaw  : 42°, 68°, 52°
> Beeper Operation  : 7 tones or no beep
> Indiocators (LED) : Green = on, ready to scan; Red=good read; Yellow =
> CodeGate™active (off); auto trigger mode (on)
>   

Biasanya yang penting dan signifikan cuman:

System Interfaces, Width of scan field, Decode Capability.

Lainnya biasanya sudah standar, kecuali fitur seperti infrared, 
bluetooth, memory (jika wireless).

Faktor lainnya adalah tipe barcode. Barcode 2D bisa menyimpan lebih 
banyak data, bahkan gambar juga bisa. Namun scannernya juga beda dengan 
barcode linear.

Number Characters Read = banyak data maksimun per pemindaian?


TR.





-- 
www.itcenter.or.id - Komunitas Teknologi Informasi Indonesia 
Gabung, Keluar, Mode Kirim : [EMAIL PROTECTED] 
## Jobs: itcenter.or.id/jobs ## Bursa: itcenter.or.id/bursa ##

## Jaket ITCENTER tersedia di http://shop.itcenter.or.id 
 
Yahoo! Groups Links

<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ITCENTER/

<*> Your email settings:
Individual Email | Traditional

<*> To change settings online go to:
http://groups.yahoo.com/group/ITCENTER/join
(Yahoo! ID required)

<*> To change settings via email:
mailto:[EMAIL PROTECTED] 
mailto:[EMAIL PROTECTED]

<*> To unsubscribe from this group, send an email to:
[EMAIL PROTECTED]

<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/
 


[ITCENTER] Barcode Scanner : Spesifikasi

2007-02-26 Terurut Topik Sulaiman
Ada yang faham "Barcode Scanner" ? Saya disuruh beli dengan
spesifikasi seperti ini. Dari list dibawah, hal-hal apa yang penting
untuk diketahui.

Trims.



Light Source: Visible Laser Diode
Laser Power : 0.72 mW (peak)
Depth of Scan   Field   : 0 mm – 203 mm (0"-8") for 0.33 mm (13 mll)
barcodes (at default setting)
Widht of scan field : 64 mm (2.5") @ face; 249 mm (9.8") @ 203 mm (8")
Scan Speed  : 72 +/- scan lines per second
-

Scan pattern: Single scan line
Infrared  Activation: Long range: 0 mm – 279 mm +/- 51 mm ( 0" - 11" +/- 2")
: Short range : 0 mm – 102 mm +/- 25 mm (0" - 4" +/- 1")
Minimum Bar Width   : 0.127 mm (5.0 mll)
Decode Capability   : Autodiscriminates all standard barcodes ; for
other symbologies call Metrologic:
System Interfaces   : RS232, Pckeyboard  wedge, USB
Print Contrast  : 35% minimum reflectance difference
Number Characters Read  : Up to 80 data characters (Maximum number will
vary based on symbology and density)
Roll, Pitch, Yaw: 42°, 68°, 52°
Beeper Operation: 7 tones or no beep
Indiocators (LED)   : Green = on, ready to scan; Red=good read; Yellow =
CodeGate™active (off); auto trigger mode (on)


-- 
www.itcenter.or.id - Komunitas Teknologi Informasi Indonesia 
Gabung, Keluar, Mode Kirim : [EMAIL PROTECTED] 
## Jobs: itcenter.or.id/jobs ## Bursa: itcenter.or.id/bursa ##

## Jaket ITCENTER tersedia di http://shop.itcenter.or.id 
 
Yahoo! Groups Links

<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ITCENTER/

<*> Your email settings:
Individual Email | Traditional

<*> To change settings online go to:
http://groups.yahoo.com/group/ITCENTER/join
(Yahoo! ID required)

<*> To change settings via email:
mailto:[EMAIL PROTECTED] 
mailto:[EMAIL PROTECTED]

<*> To unsubscribe from this group, send an email to:
[EMAIL PROTECTED]

<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/