Yeah,
We have 104's too but since they're in production, its not a good
idea to even sneeze nearthem =D.
So we're using one of our future productionMX240 with "MPCE Type 3
3D" with a "10X10GE SFP+" MIC. Pretty much the generic one for MX240
The cascade ports works enough to talk to the satellite and
convert/upgrade/downgrade them. Had no issue testing with xe-2/0/3-9
with generic stuff.
Thanks for the input.
> show chassis hardware
Hardware inventory:
Item Version Part number Description
ChassisMX240
Midplane REV 07 760-021404 MX240 Backplane
FPM BoardREV 03 760-021392 Front Panel Display
PEM 0Rev 10 740-029970 PS 1.4-2.52kW; 90-264VAC in
PEM 1Rev 06 740-029970 PS 1.4-2.52kW; 90-264VAC in
PEM 2Rev 05 740-029970 PS 1.4-2.52kW; 90-264VAC in
PEM 3Rev 07 740-029970 PS 1.4-2.52kW; 90-264VAC in
Routing Engine 0 REV 08 740-031116 RE-S-1800x4
Routing Engine 1 REV 08 740-031116 RE-S-1800x4
CB 0 REV 14 750-031391 Enhanced MX SCB
CB 1 REV 14 750-031391 Enhanced MX SCB
FPC 2REV 07 750-045372 MPCE Type 3 3D
CPUREV 08 711-035209 HMPC PMB 2G
MIC 0 REV 07 750-033307 10X10GE SFPP
PIC 0 BUILTIN 10X10GE SFPP
Xcvr 0 REV 01 740-031980 SFP+-10G-SR
Xcvr 1 REV 01 740-021308 SFP+-10G-SR
Fan Tray 0 REV 01 710-030216 Enhanced Fan Tray
set chassis redundancy routing-engine 0 master
set chassis redundancy routing-engine 1 backup
set chassis network-services enhanced-ip
set chassis satellite-management fpc 101 serial-number
set chassis satellite-management fpc 101 SAT1
set chassis satellite-management fpc 101 cascade-ports xe-2/0/1
set chassis satellite-management fpc 102 serial-number
set chassis satellite-management fpc 102 SAT2
set chassis satellite-management fpc 102 cascade-ports xe-2/0/0
set chassis satellite-management upgrade-groups GROUP1 satellite 101
set chassis satellite-management upgrade-groups GROUP2 satellite 102
set chassis satellite-management auto-satellite-conversion satellite 101
set chassis satellite-management auto-satellite-conversion satellite 102
> show chassis satellite
Device Cascade Port Extended Ports
AliasSlot State Ports State Total/Up
SAT1 101Online xe-2/0/1 online 4/4
SAT2 102Online xe-2/0/0 online 7/6
This is a Copper/SFP, same source SFP as those that are currently
working in your QFX5100, but with Junos.
> show interfaces ge-102/0/20
Physical interface: ge-102/0/20, Enabled, Physical link is Up, Extended Port
Interface index: 157, SNMP ifIndex: 546
Description:
Link-level type: Ethernet, MTU: 1500, MRU: 1508, LAN-PHY mode,
Link-mode: *Half-duplex,* Speed: Auto, BPDU Error: None,
Loop Detect PDU Error: None, Ethernet-Switching Error: None,
MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled,
Flow control: Enabled, Auto-negotiation: Enabled, Remote fault: Online,
IEEE 802.3az Energy Efficient Ethernet: Disabled, Auto-MDIX: Enabled
Pad to minimum frame size: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None
CoS queues : 8 supported, 8 maximum usable queues
Schedulers : 0
Current address: f4:b5:2f:44:48:04, Hardware address: f4:b5:2f:44:48:04
Last flapped : 2017-08-10 08:03:30 EDT (07:11:46 ago)
Input rate : 464 bps (1 pps)
Output rate: 0 bps (0 pps)
Active alarms : None
Active defects : None
Interface transmit statistics: Disabled
Logical interface ge-102/0/20.0 (Index 348) (SNMP ifIndex 552)
Flags: Up 0x4004000 Encapsulation: ENET2
Input packets : 0
Output packets: 100
Protocol inet, MTU: 1486
Max nh cache: 75000, New hold nh limit: 75000, Curr nh cnt: 0,
Curr new hold cnt: 0, NH drop cnt: 0
Flags: Sendbcast-pkt-to-re
Addresses, Flags: Is-Preferred Is-Primary
Destination: 10.25.1.12/31, Local: 10.25.1.13
Protocol multiservice, MTU: Unlimited
Flags: Is-Primary
That bold should be 10Gbps/Full, they're the same source SFP+ as
the cascade ports
> show interfaces xe-102/0/22
Physical interface: xe-102/0/22, Enabled, Physical link is Up, Extended Port
Interface index: 161, SNMP ifIndex: 550
Link-level type: Ethernet, MTU: 1514, MRU: 1522, LAN-PHY mode, Speed:
*Unspecified*, Duplex: *Unspecified*, BPDU Error: None, Loop Detect PDU
Error: None, Ethernet-Switching Error: None, MAC-REWRITE Error: None,
Loopback: Disabled, Source filtering: Disabled, Flow control: Enabled
Pad to minimum frame size: Disabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None
CoS queues : 8 supported, 8 m