Re: [j-nsp] jnxOperatingTemp issues on ex4500?

2012-02-18 Thread JP Velders
 (i.e. 
zero).

> Date: Thu, 16 Feb 2012 12:53:42 -0700
> From: Jonathan Call 
> Subject: [j-nsp] jnxOperatingTemp issues on ex4500?

> If I run 'show snmp mib walk jnxOperatingTemp' [ ... ] on an 
> ex4500-40f all of the entries return a non-operational status
> (i.e. zero). All of them are running 11.4R1.6.

Same here on 2 mixed VC's (4200-48t+4500-40f) and 1 non-mixed.

Only non-zero ones in a mixed VC are:
jnxOperatingTemp.7.1.0.0 = 0
jnxOperatingTemp.7.2.0.0 = 30
jnxOperatingTemp.7.3.0.0 = 36
jnxOperatingTemp.7.4.0.0 = 0

Which would equate to the 4200's being members 1&2 (0-3 total)...

Kind regards,
JP Velders

___
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp


[j-nsp] jnxOperatingTemp issues on ex4500?

2012-02-16 Thread Jonathan Call

If I run 'show snmp mib walk jnxOperatingTemp'  on an ex4200-24t I get valid 
(i.e. non-zero) temperature readings for the FPCs and Routing Engines in it. If 
I run the same command on an ex4500-40f all of the entries return a 
non-operational status (i.e. zero). All of them are running 11.4R1.6.
Has anyone encountered something similar?