Hello,
I'm testing 2 ASR-920-24SZ-M with XE 16.09.03 version.
The devices are connected back-to-back using Teng 0/0/25 interfaces with MPLS
enabled.
The TenG0/0/27 of both devices are connected to traffic generator instruments.
Here's the setup:
+--+
|TRAFFIC GEN|
+--
unnumbered setup. you just point individual
> tags on individial interfaces too a common EVC. Your gonna love it when you
> get your head around it.
>
>
> On 28 February 2013 10:41, Davide Ambrosi
> wrote:
>>
>> Hello Mattias,
>> but in the ME3600X (or ME3800
possible.
Thanks,
Davide
2013/2/28 Mattias Gyllenvarg :
> Do it in the 3600X, thats what there good at.
>
>
> On 28 February 2013 09:55, Davide Ambrosi
> wrote:
>>
>> Thanks Mack,
>> so I have to change all the 7603 boxes and move to 7603-S to support
>> the ES+ c
--
> From: cisco-nsp-boun...@puck.nether.net
> [mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Davide Ambrosi
> Sent: Wednesday, February 27, 2013 9:32 AM
> To: cisco-nsp@puck.nether.net
> Subject: [c-nsp] 802.1Q-in-Q VLAN Tag Termination on 7600/6500 OSN modules
>
> Hell
Hello,
We have some 7603 boxes with SUP720/SUP2 installed as main supervisor
in our MPLS Edge sites.
Now we need to terminate QinQ VLAN directly on one or more GE
interfaces of the 7603 routers because we are planning to introduce
metro ethernet tecnologies (ME3400E/ME3600X) in our fiber and
micr