Hi all

I recently had a discussion on how to connect interfaces belonging to a same 
port-channel & I would like your opinion.

On Nexus or Catalyst, I am wondering if the different interfaces of critical 
Port-Channel (for example, a port-Channel going from Core to Distribution 
switches) 
should be mixed from different ASICs/UPC (could make sense in order to get the 
maximum available bandwidth in any cases) or into the same one (I saw a Nexus 
presentation seeing that the multicast hashing distribution in a Port-Channel 
would result in replicating traffic to all UPC & then drop on the one which was 
not 
chosen by the hashing algorithm)

Would have a recommandation or best practices you use, & why ?
In addition, did anyone face issues using or one the other method ? I am 
particularly interessed in hardware limiters & CoPP behaviours

Thanks in advance

Gilles.