have mentioned here also to the page.
>>
>> [1]
>> https://cwiki.apache.org/confluence/display/STRATOS/4.1.0+Updating+an+Application
>>
>> [2]
>> https://cwiki.apache.org/confluence/display/STRATOS/4.1.0+Updating+a+Network+Partition
>>
>> Thanks,
>> Reka
>>
dating+a+Network+Partition
>
> Thanks,
> Reka
>
>>
>>
>> Thanks, Shaheed
>>
>>
>>
>> *From:* Martin Eppel (meppel)
>> *Sent:* 23 July 2015 17:25
>> *To:* dev@stratos.apache.org
>> *Subject:* RE: 4.1 Stratos testig: clarifying application u
t; *Sent:* 23 July 2015 17:25
> *To:* dev@stratos.apache.org
> *Subject:* RE: 4.1 Stratos testig: clarifying application update API
>
>
>
> Thanks Reka for the clarification, I’ll update my test case accordingly
>
>
>
> *From:* Reka Thirunavukkarasu [mailto:r...@wso2.com ]
Thanks Reka for the clarification, I’ll update my test case accordingly
From: Reka Thirunavukkarasu [mailto:r...@wso2.com]
Sent: Wednesday, July 22, 2015 11:50 PM
To: dev
Subject: Re: 4.1 Stratos testig: clarifying application update API
Hi Martin,
As we tested the scenario along with your
el)
> *Sent:* Wednesday, July 22, 2015 2:41 PM
> *To:* dev@stratos.apache.org
> *Subject:* RE: 4.1 Stratos testig: clarifying application update API
>
>
>
> Hi Reka, Pubudu
>
>
>
> I tested a scenario where I update group groupMinInstances/groupMaxInstances
> (which
4-2-0x0", "cartridges": [{"cartridgeMin": 1,
"cartridgeMax": 1, "type": "c2", "subscribableInfo": {"alias": "c2-1x0",
"deploymentPolicy": "static-2", "autoscalingPolicy": "economy
Thanks for the clarification
From: Pubudu Gunatilaka [mailto:pubu...@wso2.com]
Sent: Tuesday, July 21, 2015 11:00 PM
To: dev
Subject: Re: 4.1 Stratos testig: clarifying application update API
Hi Martin,
You can update only carridgeMin and cartridgeMax at runtime in application
update. Even you
Hi Martin,
As Pubudu explained, those are the expected steps and the result of the
application update. *Application Runtime* can only be updated with
cartridgeMin/cartridgeMax and/or with groupMinInstances/groupMaxInstances.
Even if you update other parameters, it will get ignored by the back end.
Hi Martin,
You can update only carridgeMin and cartridgeMax at runtime in application
update. Even you can update the deployment policy which uses the
application. But you cannot change the deployment policy in application at
runtime.
In your case, as you have used two different deployment polici