Re: [PATCH v3 4/4] staging: iio: ad7780: moving ad7780 out of staging

2019-02-18 Thread Jonathan Cameron
On Thu, 14 Feb 2019 18:48:15 -0200 Renato Lui Geh wrote: > On 02/09, Jonathan Cameron wrote: > >On Tue, 5 Feb 2019 15:14:03 -0200 > >Renato Lui Geh wrote: > > > >> Move ad7780 ADC driver out of staging and into the mainline. > >> > >> The ad7780 is a sigma-delta analog to digital converter. Th

Re: [PATCH v3 4/4] staging: iio: ad7780: moving ad7780 out of staging

2019-02-14 Thread Renato Lui Geh
On 02/09, Jonathan Cameron wrote: On Tue, 5 Feb 2019 15:14:03 -0200 Renato Lui Geh wrote: Move ad7780 ADC driver out of staging and into the mainline. The ad7780 is a sigma-delta analog to digital converter. This driver provides reading voltage values and status bits from both the ad778x and

Re: [PATCH v3 4/4] staging: iio: ad7780: moving ad7780 out of staging

2019-02-09 Thread Jonathan Cameron
On Tue, 5 Feb 2019 15:14:03 -0200 Renato Lui Geh wrote: > Move ad7780 ADC driver out of staging and into the mainline. > > The ad7780 is a sigma-delta analog to digital converter. This driver provides > reading voltage values and status bits from both the ad778x and ad717x series. > Its interfac

[PATCH v3 4/4] staging: iio: ad7780: moving ad7780 out of staging

2019-02-05 Thread Renato Lui Geh
Move ad7780 ADC driver out of staging and into the mainline. The ad7780 is a sigma-delta analog to digital converter. This driver provides reading voltage values and status bits from both the ad778x and ad717x series. Its interface also allows writing on the FILTER and GAIN GPIO pins on the ad778