[Histonet] RE: Xylene sensitivity

2011-09-27 Thread D'Attilio, Shelley
Hi Tom, Yes, our Employee Health & Safety department is involved with this problem. Our lab is negative pressure, but do not know the air exchange rate. I will definitely ask that to be checked. We monitor employees annually and had a full environmental assessment 2-3 years ago prior to ins

[Histonet] RE: xylene sensitivity

2011-09-27 Thread D'Attilio, Shelley
Kathryn, Thanks for the advice. I will evaluate the installation of a hood. Regards, Shelley D'Attilio MT(ASCP) Manager, Chemistry, Cytology and Histology Dept. of Pathology and Laboratory Medicine Stormont-Vail HealthCare Topeka, Kansas -Original Message- From: Stoll, Kathryn [ma

[Histonet] Re: Xylene sensitivity

2011-09-27 Thread Bob Richmond
Some points that haven't been mentioned in this discussion: I think most labs have switched from xylenes to aliphatic hydrocarbons for processing, hydration, and dehydration though obviously considerable controversy remains. (I can't imagine anybody switching from xylene to limonene now - particul