Re: Reply CONSOLE when run ZOS under ZVM

2010-11-05 Thread Alan Altmark
On Friday, 11/05/2010 at 10:03 EDT, gclo...@br.ibm.com wrote: > When not in NIPCON, we can use the "VINPUT VMSG" to reply NIP (Nucleus > Initialization Program) messages, and if this address are valid in IOCP and > CONSOLxx it "becomes normal" when Address Space "CONSOLE" starts. Remember to u

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-05 Thread gclovis
---| |01/11/2010 12:31 | >--| |> | Subject: | |> >-----------------------

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Sergio Lima
Hello Pete, Also run.. very good... thanks a lot... Sergio Date: Mon, 1 Nov 2010 14:53:22 + From: peter.bor...@northgatearinso.com Subject: Re: Reply CONSOLE when run ZOS under ZVM To: IBMVM@LISTSERV.UARK.EDU Has he tried VINPUT VMSG R00,... ? From: The IBM z/VM

Recall: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Pete Borton
Peter Borton would like to recall the message, "Reply CONSOLE when run ZOS under ZVM".

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Pete Borton
Has he tried VINPUT VMSG R00,... ? From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Sergio Lima Sent: 01 November 2010 14:39 To: IBMVM@LISTSERV.UARK.EDU Subject: Re: Reply CONSOLE when run ZOS under ZVM Hello Mike, He said

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Sergio Lima
:36:29 -0500 From: car...@illustro.com Subject: Re: Reply CONSOLE when run ZOS under ZVM To: IBMVM@LISTSERV.UARK.EDU He needs a 3270 console device at 0700 for the z/OS ADCD system. He can define it the same as his CP console (at device 0700) or he can use a different device from his CP

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Sergio Lima
mainl...@gmail.com Subject: Re: Reply CONSOLE when run ZOS under ZVM To: IBMVM@LISTSERV.UARK.EDU I don't know why you are seeing a CP READ for a z/OS prompt. Is this terminal defined to z/OS as a console? Since it's in a CP READ you may try entering Begin. then try the R 0,I On Mon,

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Chuck Arney
have adequate measures in place for your own virus checking. From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Sergio Lima Sent: Monday, November 01, 2010 9:22 AM To: IBMVM@LISTSERV.UARK.EDU Subject: Re: Reply CONSOLE when run ZOS

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Mark Pace
> > > > > > > CP READ > ZVM_BRT > > He can't responde to ZOS machine, because when entry the command, receive : > > R 00,I > HCPCMD001E Unknown CP command: R > > Thanks, > > Sergio &g

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Sergio Lima
z/VM Operating System To IBMVM@LISTSERV.UARK.EDU cc Subject Re: Reply CONSOLE when run ZOS under ZVM I'm not sure about his specific problem, but things to take into account. The default recall key for z/OS is PA1 which the default key for CP READ. A couple of things that I a

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread George Henke/NYLIC
CONSOLE when run ZOS under ZVM I'm not sure about his specific problem, but things to take into account. The default recall key for z/OS is PA1 which the default key for CP READ. A couple of things that I add to my USER DIRECT entry for all z/OS guests. COMMAND TERM BRKKEY

Re: Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Mark Pace
I'm not sure about his specific problem, but things to take into account. The default recall key for z/OS is PA1 which the default key for CP READ. A couple of things that I add to my USER DIRECT entry for all z/OS guests. COMMAND TERM BRKKEY PF12 COMMAND TERM BREAKIN GUESTCTL COMMAND SET

Reply CONSOLE when run ZOS under ZVM

2010-11-01 Thread Sergio Lima
Hello List, A friend have a question, but, his is not in this list, and for this reason I try do a favour ask this question for him. He try run ZOS under ZVM, and when need give a response (reply), the CMS machine stay under CP READ, and for this reason the IPL can't continue. I said that give