Re: [j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-08-19 Thread Richard Hesse
I can confirm that it's very much still broken in 12.3R7.7. It's not resolved in any manner. -richard On Wed, Aug 6, 2014 at 1:49 AM, Sebastian Wiesinger < juniper-...@ml.karotte.org> wrote: > * Scott Granados [2014-07-15 16:36]: > > I found more to bring this thread home. > > > > The problem

Re: [j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-08-06 Thread Sebastian Wiesinger
* Scott Granados [2014-07-15 16:36]: > I found more to bring this thread home. > > The problem I had was covered in PR963060. We discovered this problem a long time ago and there are already 1-2 threads on this ML where this has happend. Took Juniper some time to even acknowledge that there IS

Re: [j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-07-15 Thread Abhi via juniper-nsp
More on this i think it important as many folks may run into this. this PR only address the current limitation in sampled and rpd communication by the workaround mentioned PR but it does not address the limitation of reading from file itself which causes sampled to slow down in first place. The

Re: [j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-07-15 Thread Scott Granados
I found more to bring this thread home. The problem I had was covered in PR963060. Basically, a condition would take place where the sampled process would block the programming of the PFE and would break forwarding. Lots of kernel veto messages were recorded in the log and the path fr

Re: [j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-07-10 Thread Justin M. Streiner
On Wed, 9 Jul 2014, Scott Granados wrote: I have an interesting problem. I have an MX80 where I wish to enable inline flow sampling. I used the kb entry as a template and configured. When setting the table size the PFE rebooted which is expected but when it came back online forwarding stop

[j-nsp] MX80 stops forwarding after enabling inline flow sampling

2014-07-10 Thread Scott Granados
Hi, I have an interesting problem. I have an MX80 where I wish to enable inline flow sampling. I used the kb entry as a template and configured. When setting the table size the PFE rebooted which is expected but when it came back online forwarding stopped. I rebooted again and had th