I'm afraid, you have to hack the code.
In SRC_lapwso checkout the routines:
hmsec.F (see comments at the top) and
garadme.f
The latter calculates the radial matrix elements in hexl, but this is a
4 dim array (hexl(0:lomax,nato,2,9)) and you have to figure out what
you want.
Regards
Am
Hi,
I can confirm the problem, thank you very much for the report.
It seems that my previous fix, posted on 18.June 23, only partially
fixed the problem (probably just for one atom).
Please use the attached l2main.F for all lapw2_mpi calculations with the
-tau switch (mBJ or meta-GGAs).
Well, we get only part of the information each time.
You are using a 3x3x3 W supercell with H/He interstitials.
How did you initialize the calculation ? Hopefully in the new batch
type mode with a low precision (0 or 1) !! If not, then:
RKMAX=5.4 seems still very big for the presumably smal
3 matches
Mail list logo