On 21/10/2017 20:54, Richard Futrell wrote:
#

Exact sequence of steps required to reproduce the problem - Transmit about 2 or 3 times and the errors  hamlib error: communication bus error while getting current vfo frequency occurs.

#

Rig Information - IC-746

Hi Richard,

the most common cause of that error with Icom rigs is that "CI-V Transceive Mode" is enabled on the rig. Hamlib requires that CI-V Transceive mode is disabled for reliable CAT communications. Other software should not be impacted apart from a small number of applications that only work with "CI-V Transceive Mode" enabled.

73
Bill
G4WJS.

------------------------------------------------------------------------------