Hmm, Thanks Ted. I am going to have to do some more reading.
regards, Martin On 25 February 2010 19:11, Ted Dunning <ted.dunn...@gmail.com> wrote: > Not really. You have ordering guarantees and you can avoid the whole mess > by using the version numbers when you update the file. See my other email. > > On Thu, Feb 25, 2010 at 2:50 AM, Martin Waite <waite....@googlemail.com > >wrote: > > > But to do this, would I need to call sync between steps 2 and 3 to ensure > > the node "FN" was up-to-date - assuming I do not know if I am connected > to > > a > > primary ZK instance ? Would 10K sync calls within a 2 minute period be > > excessive ? > > > > > > -- > Ted Dunning, CTO > DeepDyve >