John--

Have tried the Warp filter with a scale of -1.0?

--Sam


On 11/22/2017 2:52 AM, John Mangeri wrote:
Hello,

I am working in a reduced unit system where the computed strain fields are around order 1. I could write postprocessors to rescale before visualization but that would increase my computational time.

Is there a way to turn off the automatic warping that ParaView performs on disp_k (k =x, y, z) fields?

I tried to use the WarpByVector filter with scale of 0.1 or smaller and that did not seem to work properly. I should mention I'm on version 5.0 (my favorite for a variety of reasons), so maybe the this WarpByVector issue is resolved in newer versions.

Thanks,
John