St?phane VOLTZ wrote: >Le Mercredi 1 F?vrier 2006 22:52, Maarten Storm a ?crit : > > >>Hello, >> >>I have a dell A920 printer/scanner and thought that might be working >>with the lexmark backend in 1.0.17. It didn't work and I thought it >>might have to do with the dell thing. But in the january archives I read >>a post of someone with a lexmark with the same problem but there's no >>solution there. I was wondering if a solution was found there. >>I have a debug log made while using xsane. I only hear a lot of noice >>and in the scanner seems nothing to move. >> >>Hope someone can help me, >> >>Thanks, >> >>Maarten >> >> > > Hello, > > the A920 sensor is different from the one used to develop the lexmark >backend. So it won't work with the current version.. However I am working >adding support fo it on an experimental version. It currenly scans in color >at 75/150/300 and 600 dpi. Gray scanning will come very soon. > You'll have to use CVS to get the code and compile it. You'll also need >sane-backends sources (1.0.17 or cvs). To get experimental lexmark do: > >cvs -z3 -d:pserver:anonym...@cvs.alioth.debian.org:/cvsroot/sane co >experimental/lexmark > >Then cd into experimental/lexmark and run links.sh giving it the path to the >directory where you put sane-backend sources. Let's say it's in /usr/src : >sh link.sh /usr/src/sane-backends-1.0.17 >Then cd to /usr/src/sane-backends-1.0.17, do 'configure', 'make' and 'make >install'. You should be able to run the A290. > >Regards, > Stef > > > > Thanks for your fast reply. I tried installing the experimental cvs, but still same problem. The scanner seems to start and then it locks. I think there is another problem also. I have attached the new log.
Regards, Maarten -------------- next part -------------- sh: kde-config: command not found sh: kde-config: command not found [sanei_debug] Setting debug level of lexmark to 20. [lexmark] SANE Lexmark backend version 1.0-0 [lexmark] sane_init: version_code=0xbf98189c [lexmark] attachLexmark: devname=libusb:003:009 [lexmark] sane_get_devices: device_list=0xbf9818d8, local_only=0 [lexmark] sane_open: devicename="libusb:003:009", handle=0xbf981734 [lexmark] sane_open: devname from list: libusb:003:009 [lexmark] init_options: lexmark_device = 0x82be708 [lexmark] sanei_lexmark_x1100_open_device: devnum=0 [lexmark] sane_control_option: handle=0x82be708, opt=0, act=0, val=0x80cf6d4, info=(nil) [lexmark] Option value = 6 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x832e858, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf98152c, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 3 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_control_option: handle=0x82be708, opt=4, act=0, val=0x832e8a8, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 5 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x8335830, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf981250, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x83433a0, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf9801bc, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 3 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_control_option: handle=0x82be708, opt=4, act=0, val=0x83441a8, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 5 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x83449e8, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf97fee0, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x8363a18, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf98150c, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 3 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 4 [lexmark] sane_control_option: handle=0x82be708, opt=4, act=0, val=0x8339c30, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 5 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x83362e0, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0xbf981230, info=(nil) [lexmark] Option value = 150 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_parameters: handle=0x82be708, params=0x80cf814 [lexmark] sane_get_parameters: Data size determined as f7314 [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 2ee [lexmark] depth 8 [lexmark] pixels_per_line 1c2 [lexmark] bytes_per_line 546 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=1, val=0xbf98173c, info=(nil) [lexmark] sane_get_parameters: handle=0x82be708, params=(nil) [lexmark] sane_get_parameters: Data size determined as 3e12a [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 177 [lexmark] depth 8 [lexmark] pixels_per_line e2 [lexmark] bytes_per_line 2a6 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=0, val=0x8349a70, info=(nil) [lexmark] Option value = 75 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 1 [lexmark] sane_control_option: handle=0x82be708, opt=1, act=0, val=0x8349ab0, info=(nil) [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_get_option_descriptor: handle=0x82be708, option = 2 [lexmark] sane_control_option: handle=0x82be708, opt=2, act=1, val=0xbf981b9c, info=(nil) [lexmark] sane_get_parameters: handle=0x82be708, params=(nil) [lexmark] sane_get_parameters: Data size determined as 3e12a [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 177 [lexmark] depth 8 [lexmark] pixels_per_line e2 [lexmark] bytes_per_line 2a6 [lexmark] sane_control_option: handle=0x82be708, opt=3, act=1, val=0xbf981bb8, info=(nil) [lexmark] sane_get_parameters: handle=0x82be708, params=(nil) [lexmark] sane_get_parameters: Data size determined as 3e12a [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 177 [lexmark] depth 8 [lexmark] pixels_per_line e2 [lexmark] bytes_per_line 2a6 [lexmark] sane_start: handle=0x82be708 [lexmark] sane_get_parameters: handle=0x82be708, params=(nil) [lexmark] sane_get_parameters: Data size determined as 3e12a [lexmark] sane_get_parameters: [lexmark] format: SANE_FRAME_RGB [lexmark] last_frame: TRUE [lexmark] lines 177 [lexmark] depth 8 [lexmark] pixels_per_line e2 [lexmark] bytes_per_line 2a6 [lexmark] sanei_lexmark_x1100_search_home_fwd: [lexmark] sanei_lexmark_x1100_search_home_bwd: From wolframhei...@web.de Fri Feb 3 14:46:38 2006 From: wolframhei...@web.de (Wolfram Heider) Date: Fri Feb 3 14:41:27 2006 Subject: [sane-devel] lexmark x1170 @Mdk2005 installed but not detected In-Reply-To: <43e362a8.7080...@o2.pl> References: <43e220da.3020...@o2.pl> <op.s4da76y1ibo4fx@localhost> <43e362a8.7080...@o2.pl> Message-ID: <200602031546.39381.wolframhei...@web.de> Patek, I must admit, I made a mistake pushing the wrong button while testing a new mail-client, so let's better stay in the list. The lexmark-stuff is pretty new, I even haven't included it in the sane-version on my box. So I'm not able to check if it's necessary to specify the path to the firmware in /etc/sane.d/your_driver - did you? Regards Wolfram Heider Am Freitag, 3. Februar 2006 15:03 schrieb patek: > Hi, > > Thanks for replying. Please advise if you know: do I have to reply to > you on-list other off-list? > I have tried to run scanimage, xsane and kooka both as root and as user. > > Regards, > patek > > Wolfram Heider napisa?(a): > > Patek, > > have you tried to run the frontends as root? > > > > Regards > > Wolfram Heider > > > > Am 02.02.2006, 16:10 Uhr, schrieb patek <pat...@o2.pl>: > >> Hi, > >> I am a newbie but I tried really hard to get my x1170 working as this > >> is a gift from my cousin:P > >> I managed to download the drivers from cvs (never did this before) > >> and compile them. When I type sane-find-scanner, I get > >> (...) > >> found USB scanner (vendor=0x043d, product=0x007c) at libusb:001:004 > >> (...) > >> but when I try to run scanimage -L: "No scanners were > >> identified.(...)". Kooka and Xsane don't detect it as well, no matter > >> if it is on or off. > >> I have tried to search through the archives and googled a lot, but > >> failed to finf anything. > >> Do you have any ideas? > >> Thanks for your work, guys! Regards > >> patek (Poland)