Re: [Paraview] Cell Data to Point Data with CFD wall values

2012-07-02 Thread Samuel Key
Magician, If you were using EnSight Gold formatted binary results output, you could use the EnSight Part construct to output (both in the same results file-set) the 2D-Wall elements and the 3D-Cell elements as separate displayable graphic objects (plus their point cell data). Then, in PV,

Re: [Paraview] Cell Data to Point Data with CFD wall values

2012-07-02 Thread Andy Bauer
What I would try is extract block filter to separate the 2 data sets. Then use the resample with data set to project the wall point data to the volumetric grid point data. I'm not sure if it will work without testing it though. On Mon, Jul 2, 2012 at 10:39 AM, Magician f_magic...@mac.com wrote:

[Paraview] ParaView thinks that it does not have a wind blade reader

2012-07-02 Thread Sohail Shafii
Hi, We are trying to open a .wind data set.  In the open file menu, ParaView lists the .wind format as a possible option.  Once we click open, however, it complains that a reader for that data format cannot be found.  This is true for the compiled-from-source and pre-compiled versions of

Re: [Paraview] ParaView thinks that it does not have a wind blade reader

2012-07-02 Thread Sebastien Jourdain
Hi Sohail, a similar bug was fixed in master not so long ago. Could you try master to see if the issue remains ? Thanks, Seb On Mon, Jul 2, 2012 at 5:36 PM, Sohail Shafii sohailsha...@yahoo.com wrote: Hi, We are trying to open a .wind data set. In the open file menu, ParaView lists the