Append Datasets (aka vtkAppendFilter) will do what you want.
David E DeMarle
Kitware, Inc.
RD Engineer
28 Corporate Drive
Clifton Park, NY 12065-8662
Phone: 518-371-3971 x109
On Sat, Oct 3, 2009 at 12:32 AM, Tabrez Ali st...@purdue.edu wrote:
I hope I am on the right mailing list. Apologies if
Tabrez,
If by add, you mean disply both datum-sets at the same time--
ParaView is quite happy to open and read multiple data files, for
example, meshA.vtu and meshB.vtu. You can then construct individual
filter pipelines and/or set individual display features for the two
meshes/datum-sets.
David/Berk/Samuel
Thanks for your reply.
I want to add/combine stress results in two .vtk files. They look
exactly the same but have different mesh topologies. If the topology
was same I could just pre process the data before viewing it and add
the cell results (stress in this case)
I hope I am on the right mailing list. Apologies if not.
I want to add two vtk files with different topologies. Actually the
unstructured mesh in the two files is almost the same except that one
has a number of zero volume (cohesive) elements and the other one does not.
Is this possible in