Hi all


We are currently building a building a new pc for our access grid room. I am 
having a few problems with the configuration. The pc is a Dell Precision T5400 
with the following specs:

*       Intel Quad Xeon X5450 processor@ 3.0Ghz
*       2 x 500 gig hdd's (not in any raid)
*       2x ATI FireGL v7600 512mb pcie x16 graphics cards
*       8GB (2x4 Gbsticks) 667 Mghz ECC quad channel DDR fully buffered DIMM 
memory
*       IVCE 268G PCI-E  capture card
*       Windows XP pro 32 bit with service pack 3

 Connected to the computer we have 4x Sony PTZ cameras, 1 24" dell monitor and 
2 40" Sony Bravia panels for display.





I am encountering the following issues when using the AG software:



1.      When I have multiple displays connected to the computer and open the AG 
software I get a vic menu dialog pop up. This dialog opens about 4 times for 
every video stream. It doesn't come up when I have just the Dell monitor 
connected. It is very annoying because you have to sit there clicking dismiss 
constantly. This is a link to a  screenshot of the vic menu: 
http://mtu.flinders.edu.au/documentation/vicmenu.jpg



2.      In vic the stream from port 1 on the capture card is a blue. It doesn't 
matter what source I connect to it. If I use another piece of software I can 
see the stream from that port.




3.      The capture settings in vic do not seem to change settings on the 
capture card. eg. the capture card seems to default to NTSC. If I select PAL in 
the menu it doesn't seem to change to PAL. I downloaded a piece of software 
called Amcap. Using Amcap I can change a lot of settings on the capture card 
and these settings once changed will remain when I open AG but as soon as I 
restart the computer it will loose all of the settings. Is there way of setting 
up the capture card and defaulting it so it will always start up with the same 
settings?



Any suggestions for fixes for these problems would be greatly appreciated.

Regards,

Warren

--


Warren Draffen

Audio Visual Technician

Digital Media Services

Information Services Division

Flinders University

Telephone: 8201 5161



This email message is intended only for the addressee(s) and
contains information which may be confidential and/ or copyright.
If you are not the intended recipient of this email please do not
read, save, forward, disclose or copy the contents of it and delete it
and any copies or links to this email completely and immediately from your 
system.

Reply via email to