I have an XP display machine which runs the venue client and the node configuration. My capture box for audio and video is an Ubuntu machine with 4 Hauppauge cards all identical using the bt878 chipset. I have multiple video producer services set up using streams /dev/video0 through video3 , but for some reason, when a venue is launched, all 4 of the capture windows enable the same device (/dev/video3) The interesting thing is that I can rename the streams in the node configuration on display, and the stream names make it to the capture box. For some reason, the ServiceManager just won't open teh proper device for each stream.
Once the streams are up, I can go to the menu of each stream on the capture box, and select the proper device which brings up the proper stream, but it still doesn't remember it's setting when switching venues. Thoughts? -Jim