http://bugzilla.kernel.org/show_bug.cgi?id=11857





------- Comment #4 from [EMAIL PROTECTED]  2008-10-26 20:07 -------
Created an attachment (id=18461)
 --> (http://bugzilla.kernel.org/attachment.cgi?id=18461&action=view)
try the custom DSDT, in which the ECOK flag will be initialized correctly.

Hi, Sumant
    From the acpidump it seems that there exists the following error.  There
exists the EC device. But after the EC is initialized, the ECOK flag is still
Zero. 
    >Method (_REG, 2, NotSerialized)
                    {
                        If (LEqual (Arg0, 0x03)) {                             
  }
                    }
     Will you please try the custom DSDT and see whether the problem still
exists? In the custom DSDT the ECOK flag will be initialized when the EC _REG
object is evaluated.
     How to use the custom DSDT can be found in 
    http://www.lesswatts.org/projects/acpi/faq.php
    Thanks.



-- 
Configure bugmail: http://bugzilla.kernel.org/userprefs.cgi?tab=email
------- You are receiving this mail because: -------
You are the assignee for the bug, or are watching the assignee.

-------------------------------------------------------------------------