https://bugzilla.kernel.org/show_bug.cgi?id=215882
Bug ID: 215882
Summary: Battery not charging, Nuvision Solo 10 Draw (Intel
Cherry Trail, battery INT33F4)
Product: ACPI
Version: 2.5
Kernel Version: 5.17.4
Hardware: x86-64
OS: Linux
Tree: Mainline
Status: NEW
Severity: normal
Priority: P1
Component: Power-Battery
Assignee: [email protected]
Reporter: [email protected]
Regression: No
Created attachment 300797
--> https://bugzilla.kernel.org/attachment.cgi?id=300797&action=edit
acpidump
My issue seems remarkably similar to this issue filed here. But with a
different tablet computer, the Nuvision Solo 10 Draw.
https://bugzilla.redhat.com/show_bug.cgi?id=1610545
Running the following commands as root from that page
modprobe i2c-dev
i2cset -y -f 6 0x34 0x82 0xf0
i2cset -y -f 6 0x34 0x84 0xf0
seems to solve the issue allowing the battery to charge and stopping the red
light indicator from blinking.
Operating System: Arch Linux
Kernel: 5.17.4-arch1-1
Attached some information about the battery and system.
--