On Fri, Mar 14, 2008 at 11:02 AM, Laux Karsten-Olaf <[EMAIL PROTECTED]> wrote: > > > From what I read in the AT91 headers, the difference between SAM9263 and > other AT91s is that > > the TC interrupt is shared. Are you sure you do not get problems with this > ? > > Yepp, this is the "problem". The TCB-clock is not found in > at91_ipipe_time.c: the setup-code looks for "at91_tc0", but there is only a > "at91_tcb" clock. > > Below is a patch which should avoid this problem. The patch was created on > base of linux-2.6.24 + adoes-ipipe-2.6.24-arm-1.9.00. > > > Thanks for your hint,
Actually, I was not thinking about a clock issue. Anyway, your patch is fine, will merge, thanks. -- Gilles Chanteperdrix _______________________________________________ Adeos-main mailing list [email protected] https://mail.gna.org/listinfo/adeos-main