On 05/05/2011 05:23 PM, Alexey Galakhov wrote:
> On 05/05/2011 08:42 PM, Gilles Chanteperdrix wrote:
>> On 05/05/2011 04:12 PM, Alexey Galakhov wrote:
>>> On 05/05/2011 08:02 PM, Gilles Chanteperdrix wrote:
>>>> On 05/05/2011 03:16 PM, Alexey Galakhov wrote:
>>>>> May it be caused by the following code from plat-samsung/time.c ?
>>>>>
>>>>> static inline void set_dec(unsigned long reload)
>>>>> {
>>>>>         __raw_writel(reload, S3C2410_TCNTB(4)); /* <-------- In fact,
>>>>> TCNT is 16-bit, so what if reload > 0xffff and reload & 0xffff == 0 ??? */
>>>> Try adding:
>>>>
>>>> if (reload > 0xffff)
>>>>    reload = 0xffff;
>>>>
>>>> before the raw_writel
>>> No effect. It may make sense but does not fix this bug.
>> It may also happen that the timer has a lower limit, when the reload
>> parameter is below this limit, you shoud call ipipe_trigger_irq, as
>> explained in the porting guide.
> Seems to be not the case but tried it anyway (guessed lower limit
> 0x00ff), no effect. Also tried to add printk to __ipipe_mach_set_dec,
> got the following:

This is probably the same issue as I had on AT91. Please try disabling
the NO_HZ configuration option.

-- 
                                            Gilles.