     Well , the problem wasn't because of the light.

     IBM CE adjusted the X Bumper a bit on S10 frame and the problem is
     fixed.

     Thanks everbody for their inputs.

     Mahesh


______________________________ Forward Header __________________________________
Subject: Re: Very Strange Problem related to IBM 3494 library
Author:  rbs ([EMAIL PROTECTED]) at internet
Date:    15-02-01 1:25 AM


>     3.) I get following message on the library manager console:
>
>     A cartridge could not be released from Gripper 1 , Accessor A

Grippage problems can indicate an alignment problem in the 3494 frame.
The 3494's robot has no "eyes" to see where it's going, but rather
remembers where all positions are within the unit by virtue of its most
recent Teach operation.  If the reality of alignments change,
it spells trouble.  We recently had problems with dropped tapes and
tapes sticking out of cells after rough CE treatment of the frames
during a recent 3590 drives upgrade.  Our experienced CE came in,
adjusted the frames, did a re-Teach, and all has been well.

  Richard Sims, BU