I was getting the exact same sense data errors
from my 3583.  I ended up doing two things.  There
was a piece of clear plastic tape on the fudical
label of the I/O station that I removed.  This
seemed to clear up errors on the display of the
3583.  Next, I had the picker assembly replaced.
Things have been running flawlessly ever since.

--David Nash
  Systems Administrator
  The GSI Group

----- Original Message -----
From: "Mahesh Tailor" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, June 14, 2001 11:07 AM
Subject: Re: TSM and 3583 LTO Library


> Here's my q drive output:
>
> Library Name     Drive Name       Device Type     Device               ON
> LINE
> ------------     ------------     -----------     ----------------
> -------------------
> 3575LIB          RMT0             3570            /dev/rmt0
> Yes
> 3575LIB          RMT1             3570            /dev/rmt1
> Yes
> 3575LIB          RMT2             3570            /dev/rmt2
> Yes
> 3575LIB          RMT3             3570            /dev/rmt3
> Yes
> 3575LIB          RMT4             3570            /dev/rmt4
> Yes
> 3575LIB          RMT5             3570            /dev/rmt5
> Yes
> 3583LIB          RMT6             LTO             /dev/rmt6
> Yes
> 3583LIB          RMT7             LTO             /dev/rmt7
> Yes
> 3583LIB          RMT8             LTO             /dev/rmt8
> Yes
>
> I had not done an audit library, I just executed that command.  Here's
> the audit library log entries:
>
> 06/14/01   12:04:09      ANR8461I AUDIT LIBRARY process for library
> 3583LIB
>                           completed successfully.
>
> 06/14/01   12:04:09      ANR0985I Process 84 for AUDIT LIBRARY running in
> the
>                           BACKGROUND completed with completion state
> SUCCESS at
>                           12:04:09.
>
> And, then tried the label and checkin again but it failed with the same
> set of errors.
>
> Mahesh
>
> >>> [EMAIL PROTECTED] 06/14/01 11:50AM >>>
> Haven't worked with this library but:
> Do a   q drive and make sure drives are there and online.
> Did you do an audit library after setting up the new library?
>
> David Longo
> >>> [EMAIL PROTECTED] 06/14/01 11:45AM >>>
> Hello, all!
>
> I have just SCSI attached an IBM 3583 LTO library to my TSM server.
> Installed the latest verstion of Atape and AIX recognizes the library as
> follows:
>
> rmt6 Available 10-68-00-0,0 IBM 3580 Ultrium Tape Drive
> rmt7 Available 10-68-00-1,0 IBM 3580 Ultrium Tape Drive
> rmt8 Available 10-68-00-2,0 IBM 3580 Ultrium Tape Drive
> smc1 Available 10-68-00-6,0 IBM 3583 Library Medium Changer
>
> Here's what I have:
>
> - Atape 6.0.4.0
> - AIX 4.3.2.0
> - TSM 3.7.4.0.
> - 3583 firmware 2.05.0003 and sled version 2.01.0001
>
> Once the OS recognized the library, I executed the following commands to
> define the library in TSM.
>
> DEFINE LIBRARY 3583lib libtype=scsi device=/dev/smc1
> DEFINE DRIVE 3583lib RMT6 device=/dev/rmt6 element=256
> DEFINE DRIVE 3583lib RMT7 device=/dev/rmt7 element=257
> DEFINE DRIVE 3583lib RMT8 device=/dev/rmt8 element=258
> DEFINE DEVCLASS 3580 devtype=lto format=ultriumc libra=3583lib
> estcapa=100G
> DEFINE STGPOOL ONSITE 3580 DESCRIPTION="3583 LTO Library"
>                           ACCESS=READWRITE MAXSIZE=NOLIMIT HIGHMIG=90
> LOWMIG=70
>                           COLLOCATE=NO RECLAIM=100 MAXSCRATCH=999
> REUSEDELAY=0
>                           MIGDELAY=0 MIGCONTINUE=YES
>
> The commands all ran successfully.  I then tried to label and checkin a
> tape.  I issued the following command:
>
> LABEL libv 3583lib search=b labels=b checkin=
>
> I replied the REQUEST and then after about 30 seconds the command
> completes without doing anything with the tape.  I get the following
> entries in the actlog.
>
> 06/13/01   14:01:07      ANR8373I 003: Fill the bulk entry/exit port of
> library
>                           3583LIB with all LTO volumes to be processed
> within 60
>                           minute(s); issue 'REPLY' along with the
> request
> ID when
>                           ready.
>
> 06/13/01   14:01:11      ANR2017I Administrator ADMIN issued command:
> REP
> 003
> 06/13/01   14:01:11      ANR8499I Command accepted.
>
> 06/13/01   14:01:21      ANR8300E I/O error on library 3583LIB
> (OP=00006C03,
>                           CC=207, KEY=05, ASC=83, ASCQ=03,
>
>
> SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.83.03.46.00.00-
>                           .00., Description=Device is not in a state
> capable of
>                           performing request).  Refer to Appendix B in
> the
>                           'Messages' manual for recommended action.
>
> 06/13/01   14:01:21      ANR9999D mmsscsi.c(11395): Could not move
> volume
> from slot
>                           16 to slot 257.
>
> 06/13/01   14:01:21      ANR8841I Remove volume from slot 16 of library
> 3583LIB at
>                           your convenience.
>
> 06/13/01   14:01:22      ANR8802E LABEL LIBVOLUME process 47 for library
> failed.
> 06/13/01   14:01:22      ANR0985I Process 47 for LABEL LIBVOLUME running
> in the
>                           BACKGROUND completed with completion state
> FAILURE at
>                           14:01:22.
>
> Yes, the library is online when I do this. :-)
>
> Has anyone seen this?  What can I do to fix the problem?  Have I missed
> a
> step?
>
> TIA
>
> Mahesh Tailor
> WAN Administrator
> Carilion Health System
> Voice: 540-224-3929
> Fax: 540-224-3954
>
>
>
> "MMS <health-first.org>" made the following
>  annotations on 06/14/01 11:53:14
> ------------------------------------------------------------------------------
> This message is for the named person's use only.  It may contain
> confidential, proprietary, or legally privileged information.  No
> confidentiality or privilege is waived or lost by any mistransmission.  If
> you receive this message in error, please immediately delete it and all
> copies of it from your system, destroy any hard copies of it, and notify
> the sender.  You must not, directly or indirectly, use, disclose,
> distribute, print, or copy any part of this message if you are not the
> intended recipient.  Health First reserves the right to monitor all e-mail
> communications through its networks.  Any views or opinions expressed in
> this message are solely those of the individual sender, except (1) where
> the message states such views or opinions are on behalf of a particular
> entity;  and (2) the sender is authorized by the entity to give such views
> or opinions.
>
> ==============================================================================
>

Reply via email to