i found the answer, the dev  classes for my storage pools that
weren't reclaiming only had mountl=1

once i set them to mountl=2 thay started to reclaim

thanks


----- Original Message -----
From: "David Longo" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Wednesday, March 06, 2002 1:15 PM
Subject: Re: reclamation question


One thing to check is do this if there is no reclamation going on:
upd stg nt_tape recla=100

wait then for over one minute and then
upd stg nt_tape recla=60

Then look at actlog for last few minutes and see if there
are any error or informational messages .

If nothing and reclamation is not happening for this tape
then try a move data as someone else suggested.

David Longo

David Longo

>>> [EMAIL PROTECTED] 03/06/02 12:34PM >>>
i have a particular tape in a storage pool
that is not being reclamed



                   Volume Name: A00044
             Storage Pool Name: NT_TAPE
             Device Class Name: NT3590
       Estimated Capacity (MB): 98,244.1
                      Pct Util: 8.2
                 Volume Status: Full
                        Access: Read/Write
        Pct. Reclaimable Space: 91.9
               Scratch Volume?: Yes
               In Error State?: No
      Number of Writable Sides: 1
       Number of Times Mounted: 46
             Write Pass Number: 1
     Approx. Date Last Written: 10/26/2001 11:05:44
        Approx. Date Last Read: 10/29/2001 14:01:42
           Date Became Pending:
        Number of Write Errors: 0
         Number of Read Errors: 0
               Volume Location:
Last Update by (administrator):
         Last Update Date/Time: 10/16/2001 11:14:34




----- Original Message -----
From: "David Longo" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Wednesday, March 06, 2002 11:42 AM
Subject: Re: reclamation question


Maybe the storage pools don't have any tapes that meet criteria.
To check run this select statement:

select volume_name,pct_reclaim from volumes
where stgpool_name='STG' order by pct_reclaim

Put your stg pool name in place of 'STG" and remember use upper case.
(Put command in one line, I just broke into two for this mail).

At the end of the list you will see if any tapes have gretater than 60%
reclaimable space and which tapes.

David Longo

>>> [EMAIL PROTECTED] 03/06/02 11:03AM >>>
have tape storage pools defined wth default reclamation threshold set to 60%

some of these tape storage pools have been doing automatic reclamation ok
but a few others are not running reclamation

i cant seem to find the difference between the storasge pools



Tim Brown
Systems Specialist
Information Systems
Central Hudson Gas & Electric
tel: 845-486-5643
fax: 845-586-5921



"MMS <health-first.org>" made the following
 annotations on 03/06/02 11:55:32
----------------------------------------------------------------------------
--
This message is for the named person's use only.  It may contain
confidential, proprietary, or legally privileged information.  No
confidentiality or privilege is waived or lost by any mistransmission.  If
you receive this message in error, please immediately delete it and all
copies of it from your system, destroy any hard copies of it, and notify the
sender.  You must not, directly or indirectly, use, disclose, distribute,
print, or copy any part of this message if you are not the intended
recipient.  Health First reserves the right to monitor all e-mail
communications through its networks.  Any views or opinions expressed in
this message are solely those of the individual sender, except (1) where the
message states such views or opinions are on behalf of a particular entity;
and (2) the sender is authorized by the entity to give such views or
opinions.

============================================================================
==



"MMS <health-first.org>" made the following
 annotations on 03/06/02 13:28:11
----------------------------------------------------------------------------
--
This message is for the named person's use only.  It may contain
confidential, proprietary, or legally privileged information.  No
confidentiality or privilege is waived or lost by any mistransmission.  If
you receive this message in error, please immediately delete it and all
copies of it from your system, destroy any hard copies of it, and notify the
sender.  You must not, directly or indirectly, use, disclose, distribute,
print, or copy any part of this message if you are not the intended
recipient.  Health First reserves the right to monitor all e-mail
communications through its networks.  Any views or opinions expressed in
this message are solely those of the individual sender, except (1) where the
message states such views or opinions are on behalf of a particular entity;
and (2) the sender is authorized by the entity to give such views or
opinions.

============================================================================
==

Reply via email to