Hello Gerald, you have to change your conf files like this: lb.conf if the scsi target and luns for your libraries are OK, you do not have to change this file.
op.conf replace all "lb" with "op" (in this file you define only optical drives, not changer). For each optical drive create one stanza with correct target and lun of each drive (so you will have 10 stanzas in your conf file). Example Name="op" class="scsi" Target=X lun=Y; X is SCSI target ID of optical drive and Y is LUN of that drive mt.conf here replace "lb" with "mt" (in this file you define only tape drives, not changer). For each tape drive create one stanza with correct target and lun of each drive (so you will have 4 stanzas in your conf file). Example Name="mt" class="scsi" Target=X lun=Y; X is SCSI target ID of tape drive and Y is LUN of that drive Ing. Jozef Zatko Login a.s. Dlha 2, Stupava tel.: (421) (2) 60252618 Gerald Wichmann <[EMAIL PROTECTED]> Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> 11.07.2002 01:14 Please respond to "ADSM: Dist Stor Manager" To: [EMAIL PROTECTED] cc: Subject: solaris experts plz help Below is the output of my server's probe-scsi-all.. I have 2 ATL M1500 LTO libraries with 2 drives each, and one HP 1200ex optical library with 10 optical drives. I need to populate the "mt.conf", "lb.conf", and "op.conf" files accordingly but what I've done doesn't seem to be working. When doing the add_drv command, it loads the device driver but then fails to attach. When I do add_drv for "op" it works but I only get a "0op" and "1op" so I'm not sure why it didn't pick up 10 drives. So my first question is, what do I put in the various conf files? I'm not as familiar with solaris so could use some help. Currently my files look like this: Lb.conf Name="lb" class="scsi" Target=5 lun=0; Name="lb" class="scsi" Target=4 lun=0; Name="lb" class="scsi" Target=4 lun=1; Op.conf Name="lb" class="scsi" Target=4 lun=0; Name="lb" class="scsi" Target=4 lun=1; Mt.conf Name="lb" class="scsi" Target=5 lun=0; Name="lb" class="scsi" Target=4 lun=0; Probe-scsi-all: /pci@1f,2000/pci@1/scsi@5 Target 0 Unit 0 Removable Medium changer M4 DATA MagFile 2.10 Target 1 Unit 0 Removable Tape HP Ultrium 1-SCSI E15V Target 2 Unit 0 Removable Tape HP Ultrium 1-SCSI E15V /pci@1f,2000/pci@1/scsi@4 Target 0 Unit 0 Removable Medium changer M4 DATA MagFile 2.10 Target 1 Unit 0 Removable Tape HP Ultrium 1-SCSI E15V Target 2 Unit 0 Removable Tape HP Ultrium 1-SCSI E15V /pci@1f,4000/scsi@4,1 Target 2 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 3 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 4 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 5 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 6 Unit 0 Removable Device type 8 HP C1107J 1.40 /pci@1f,4000/scsi@4 Target 1 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 2 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 3 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 4 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 5 Unit 0 Removable Device type 7 HP C1113J 1.10 Target 6 Unit 0 Removable Device type 7 HP C1113J 1.10 Gerald Wichmann Senior Systems Development Engineer Zantaz, Inc. 925.598.3099 (w)