Hi all, 07/24/03 15:35:06 ANR8788W Unable to read the barcode of cartridge in
slot-id 1063 in library 3584LIB; loading in drive to read label. 07/24/03 15:35:06 ANR8300E I/O error on library 3584LIB (OP=00006C03, CC=207, KEY=05, ASC=30, ASCQ=00, SENSE=70.00.05.00.00.0- 0.00.0A.00.00.00.00.30.00.00.C0.00.04., Description=Dev- ice is not in a state capable of performing request). Refer to Appendix D in the 'Messages' manual for recommended action. 07/24/03 15:35:06 ANR2017I Administrator KAREL issued command: QUERY PROCESS 07/24/03 15:35:06 ANR9999D mmsscsi.c(9401): ThreadId<28> Could not move volume NOT KNOWN from slot 1063 to slot 262. 07/24/03 15:35:07 ANR8460E AUDIT LIBRARY process for library 3584LIB failed. 07/24/03 15:35:07 ANR0985I Process 32 for AUDIT LIBRARY running in the BACKGROUND completed with completion state FAILURE at 15:35:07. os'ses=AIX + win2k TSM=4.2.2.13 (AIX) + 5.1.7.0 (win2k) Libraries=both 3584 On both sites we had some problems with tapes stuck in drives. On both sites we had to do audit libraries to get TSM in synch with the libraries. While the tapes were stuck in the drive, the audit library failes and now one of the slots is empty (tape was in the drive and is completely gone) and still the audit fails. Has anyone seen this type of behavour? Is it a TSM thing (don't think so because of the version difference between sites) or has something been altered in the microcode of the library what changes things? Regard, Karel