Has anyone had any luck mixing LTO1 and LTO2 Drives in an IBM3583. We have installed 
it at one of the sites and it worked for a week and then just stopped working. We are 
working with IBM Hardware, Software (Developers who write the Drive microcodes and TSM 
for about 4 months now without any progress).

Any help is appreciated.

Rajesh Oak
Blue Cross Blue Shield of Michigan
313-225-8086

--

--------- Original Message ---------

DATE: Thu, 10 Jun 2004 15:16:46
From: "Warren, Matthew (Retail)" <[EMAIL PROTECTED]>
To: [EMAIL PROTECTED]
Cc:

>...
>
>You can actually mix lto media and drives without partitioning the
>library at 5.2. We have roughly 1/2 & 1/2 LTO1 and LTO2 media, with 12
>LTO1 and 12 LTO2 drives all in the same 3584. We also have two servers
>acting as library client/manager pairs to each other and utilise storage
>pools of both device classes remotely as well as locally.
>
>We have 2 device classes defined, each with a mount limit of 12, where
>you have to be carefull is that you don't specify a FORMAT of 'drive',
>rather you have to specify ultrium/ultriumc or ultrium2/ultrium2c.
>
>Matt.
>
>-----Original Message-----
>From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of
>Stapleton, Mark
>Sent: Thursday, June 10, 2004 3:12 PM
>To: [EMAIL PROTECTED]
>Subject: Re: LTO1 tapes in LTO2 drives
>
>From:   Cynthia Leon [mailto:[EMAIL PROTECTED]
>>I am also getting ready to add 2 LTO2 drives to a library that
>>has 10 LTO1
>>drives.  I have been told by IBM that I must partition my 3584
>>and define 2 libraries.  Is this true?
>
>From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On
>Behalf Of Steve Hartland
>>If you are using TSM 5.2 or higher, you can define 2
>>device classes instead of partitioning the library.
>
>Steve--
>
>How do you associate two different devices classes to one library?
>
>--
>Mark Stapleton
>
>
>___________________________ Disclaimer Notice __________________________
>This message and any attachments are confidential and should only be read by those to 
>whom they are addressed. If you are not the intended recipient, please contact us, 
>delete the message from your computer and destroy any copies. Any distribution or 
>copying without our prior permission is prohibited.
>
>Internet communications are not always secure and therefore the Powergen Group does 
>not accept legal responsibility for this message. The recipient is responsible for 
>verifying its authenticity before acting on the contents. Any views or opinions 
>presented are solely those of the author and do not necessarily represent those of 
>the Powergen Group.
>
>Registered addresses:
>
>Powergen UK plc, Westwood Way, Westwood Business Park,
>Coventry CV4 8LG.
>Registered in England & Wales No. 2366970
>
>Powergen Retail Limited,  Westwood Way, Westwood Business Park,
>Coventry CV4 8LG.
>Registered in England and Wales No: 3407430
>
>Telephone     +44 (0) 2476 42 4000
>Fax                +44 (0) 2476 42 5432
>



____________________________________________________________
Find what you are looking for with the Lycos Yellow Pages
http://r.lycos.com/r/yp_emailfooter/http://yellowpages.lycos.com/default.asp?SRC=lycos10

Reply via email to