Roland,

Be aware that your reusedelay parameter should be the same as the number of days back 
that you keep TSM DB Backups for.

This ensures that should you need to restore to a database backup other than the most 
recent, data will still be where the older DBBackup thinks it is.

Matt.

_-'-_
  -|-


-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Roland Scharlau
Sent: Tuesday, October 19, 2004 11:44 AM
To: [EMAIL PROTECTED]
Subject: AW: tape status is pending (?)

Hi Michael,

i changed the parameter to 3 days and deleted the volume.
Now i define it again.
Many thanks for yor answer.

Nice day
Roland



-----Ursprüngliche Nachricht-----
Von: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] Im Auftrag von Michael Garnebode
Gesendet: Dienstag, 19. Oktober 2004 12:38
An: [EMAIL PROTECTED]
Betreff: AW: tape status is pending (?)


Hi,

look at storgepool definition "reusedelay" parameter
 "q stg COPYPOOL f=d"
After a volumes comes empty the volume change his status to pending 
if reuse delay is defined on storagepool.

You can delete the volume for reuse.
Regards

Michael 

-----Ursprüngliche Nachricht-----
Von: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] Im Auftrag von Roland Scharlau
Gesendet: Dienstag, 19. Oktober 2004 12:18
An: [EMAIL PROTECTED]
Betreff: tape status is pending (?)


Hello,

has anybody an idea when a tape get this status:

Volume Name 000086L1 
Storage Pool Name COPYPOOL 
Device Class Name LTOCLASS1 
Estimated Capacity (MB) 0.0 
Scaled Capacity Applied - 
Pct Util 0.0 
Volume Status PENDING 
Access READWRITE 
Pct. Reclaimable Space 0.0 
Scratch Volume? NO 
In Error State? NO

If i update this tape, TSM will change it after a few time to pending. Many thanks for 
any idea.

Roland Scharlau

>>> Mail is virus-checked by Symantec Mail Security <<<


>>> Mail is virus-checked by Symantec Mail Security <<<


___________________________ Disclaimer Notice __________________________
This message and any attachments are confidential and should only be read by those to 
whom they are addressed. If you are not the intended recipient, please contact us, 
delete the message from your computer and destroy any copies. Any distribution or 
copying without our prior permission is prohibited.

Internet communications are not always secure and therefore Powergen Retail Limited 
does not accept legal responsibility for this message. The recipient is responsible 
for verifying its authenticity before acting on the contents. Any views or opinions 
presented are solely those of the author and do not necessarily represent those of 
Powergen Retail Limited. 

Registered addresses:

Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 8LG.
Registered in England and Wales No: 3407430

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

Reply via email to