Wanda, Persistent binding is very easy to setup in a Windows environment. We could all argue at great length on whether it should be handled by MS better but nearly all HBA manufacturers have a mechanism to setup persistent binding. Specifically we use Emulex cards and there is a utility that comes with the drivers for the HBA that lets you do this. Again, very easily all you have to do is read the doc. I know that QLogic and JNI also have this feature.
So MS doesn't take care of it but the manufacturers of the HBA's do. Kyle "Prather, Wanda" <[EMAIL PROTECTED]> wrote: Could use some help from any Windows gurus out there: HOW do I keep Windows from changing the addresses of the TSM devices? This server is Win2K3 (but the same thing has occurred on Win2K), TSM is 5.2.2.5. There are fibre connections from 2 HBA's to 2 different SAN switches. 1 Fibre cable from each SAN switch to 1 LTO drive in a 3583 (that way if we lose a switch, we can still access at least 1 drive). Yesterday in order to clean up a big tangle of fibre cables, the Windows admin disconnected 1 fibre cable from the HBA, untangled things and plugged the cable back into the HBA, EXACTLY the same connection. Repeat for the other cable. Windows RENUMBERED the library and tape drives (For example, mt2.0.0.2 became mt1.0.0.2). I saw the same thing once after a power outage, when the server came up before the switch was powered up. Now, I know that to get TSM working again, all I have to do is install the LTO drivers for these "new" devices, and update the TSM path for each device. But I would really like to understand WHY this happens, and how we can avoid it. I would like to go on vacation one day, without worrying that this should happen while I'm gone! Any insight appreciated! Wanda Prather "* I/O, I/O, It's all about I/O *" -(me) --------------------------------- Discover Yahoo! Find restaurants, movies, travel & more fun for the weekend. Check it out!