Look at IC45931 it tells you how to identify and correct differences between your primary and copy storage pools.
-----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] Behalf Of Dirk Kastens Sent: Wednesday, November 02, 2005 4:37 AM To: ADSM-L@VM.MARIST.EDU Subject: Re: Checking to make sure TSM Primary and Copypools are in Sync Hi, Mark D. Rodriguez schrieb: > select stgpool_name as "Storage Pool",sum(num_files) as "Number of > Files", - > sum(physical_mb)/1024 as "Total Physical GBs" from - > occupancy group by stgpool_name Wouldn't a "BACKUP STGPOOL <primary pool> <copypool> PREVIEW=Y" be sufficient to get the number of files and the amount of data? Or does it take too long? If the result is not null you know that the pools are not in sync. -- Regards, Dirk Kastens Universitaet Osnabrueck, Rechenzentrum (Computer Center) Albrechtstr. 28, 49069 Osnabrueck, Germany Tel.: +49-541-969-2347, FAX: -2470