Another thing we have seen with Qualstar libraries and later versions of TSM is a problem like this if you do not have the Drive Last parameter in the library set correctly. For instance, if you only have eight drives in your twelve drive library you need to ensure that drive last says 8 and not 12.
Kelly J. Lipp VP Manufacturing & CTO STORServer, Inc. 485-B Elkton Drive Colorado Springs, CO 80907 719-266-8777 [EMAIL PROTECTED] -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Roger Deschner Sent: Tuesday, May 29, 2007 12:20 PM To: ADSM-L@VM.MARIST.EDU Subject: Re: [ADSM-L] Audit library problem. We've seen something like this. It was a tape library microcode bug, not a TSM problem. It's still unresolved, though it only bites us about once a year. Still in a finger-pointing dispute with Quantum over their library microcode. Looking at your time stamps, it appears that your library is giving back its stored inventory to TSM, and that it has become corrupted. So you've got to force the library to actually re-read all the barcodes, instead of regurgitating them from its own (corrupted) memory. A first step would be to power-cycle the library and also restart the TSM server. Roger Deschner University of Illinois at Chicago [EMAIL PROTECTED] ======= "Copy protection: a headache only for the law-abiding." ======== =========================== --New York Times =========================== On Mon, 28 May 2007, Erik Björndell wrote: >Hi All! >Have anyone experienced any problems like this one below? > > >05/28/07 14:08:02 ANR8457I AUDIT LIBRARY: Operation for library >TLS-412180 > started as process 15. (SESSION: 15, PROCESS: 15) >05/28/07 14:08:03 ANR8788W Unable to read the barcode of cartridge in > slot-id 16 in library TLS-412180; loading in drive > to > read label. (SESSION: 15, PROCESS: 15) >05/28/07 14:08:03 ANR8300E I/O error on library TLS-412180 (OP=C0106C03, > CC=207, KEY=05, ASC=21, ASCQ=01, > > SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.21.01.00.C0.00- > .02., Description=Device is not in a state capable of > performing request). Refer to Appendix D in the > 'Messages' manual for recommended action. (SESSION: > 15, > PROCESS: 15) >05/28/07 14:08:03 ANR8942E Could not move volume NOT KNOWN from >slot-element > 16 to slot-element 63000. (SESSION: 15, PROCESS: 15) >05/28/07 14:08:03 ANR8460E AUDIT LIBRARY process for library TLS-412180 > failed. (SESSION: 15, PROCESS: 15) > > >Erik Björndell >SYSTEMS SPECIALIST > >Zetup by Semcon >Mellanvägen 7, SE-461 38 Trollhättan, Sweden Mobile +46(0)736 84 04 06 >E-mail [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> >www.zetup.se <http://www.zetup.se/> > > >