How nice. Fortunately, we have an entire (redundant) fabric dedicated to
TSM, and only have on initiator in each zone.

On Wed, Sep 29, 2010 at 2:38 PM, Strand, Neil B. <nbstr...@leggmason.com>wrote:

> Something we have noticed is that when an AIX server is zoned to the
> same FC port(s) on the storage device as a windows or Linux server, the
> AIX server tends to have reduced throughput when both servers are
> accessing the storage.  It appears that the AIX is given a lower
> priority of service.  I have observed this on NetApp and XIV attached to
> Cisco fabrics but have not had time to really dig into it.
>


--
Met vriendelijke groeten,

Remco Post, PLCS

Reply via email to