That may work for most radios limited by 4 possibly 6 450i or something
equivalent.
If running medusa 3.65 and 5.7 radios youll need #8 min by 2 pair pvc
jacket or better for outdoor operation.
We have a few like this and learned the hard way even with #10 hybrid
cable that would not fly due to the loss in the wire at 250'
We use Tactical SM fiber LC-LC pre-terminated
We also use Duracomms
https://duracomm.com/product-category/rack-mount-power-supplies/centri-series-he1u-mu/
Note we use the 50Amp version of this.
Youll need most of it to get to the top to sustain that 48vDC those
beast need lol.
We now have our 3rd site up with Fiber going to everything and #8
stranded pairs up the tower for power.
Also, be sure and add in the surge stuff.
On 3/30/20 4:46 PM, TJ Trout wrote:
I've been thinking of offering hybrid fiber / 12 awg copper
pre-terminated cables... if anyone has a desire for such a thing, let
me know the fiber count, connector type and lengths you would want...
On Mon, Mar 30, 2020 at 2:35 PM Matt <matt.mailingli...@gmail.com
<mailto:matt.mailingli...@gmail.com>> wrote:
What is everyone using for fiber up tower? What using for connectors?
--
AF mailing list
AF@af.afmug.com <mailto:AF@af.afmug.com>
http://af.afmug.com/mailman/listinfo/af_af.afmug.com
--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com