48 volt flooded cell batts need 54-56 volts to stay charged.  It is a telco 
standard voltage.

Sent from my iPhone

> On Jul 6, 2023, at 4:34 PM, Carl Peterson <cpeter...@portnetworks.com> wrote:
> 
> 
> I've got a design that uses a Mikrotik Fiberbox Plus as pretty much an SFP+ 
> holder for a TiBit XGS Gpon module.  Mikrotik says Max power is 57V.
> 
> I have a power design using a DRS240 that has max power of 57.6V  on vBoost.  
> 
> Any thoughts on the real magix smoke release point on a Mikrotik?  
> 