That makes me wonder if the other guys’ “10gig” surge suppressor is going to 
break what I plug into it.

I’ll tell you, compared to any other ethernet surge suppressor the 10gig model 
they sell has almost nothing in it.  If it works, it’s got to be the most 
minimal protection imaginable.  

This is probably another point in favor of separate power+fiber for outdoor 
equipment.

 

-Adam

 

 

From: ch...@go-mtc.com <ch...@go-mtc.com> 
Sent: Thursday, August 17, 2023 11:14 PM
To: dmmoff...@gmail.com; 'AnimalFarm Microwave Users Group' <af@af.afmug.com>
Subject: Re: [AFMUG] Question for Chuck, and anyone wise who wants to add their 
0.02...

 

I have not.  It is nearly impossible for a surge suppressor to pass full CAT6 
standards.  The jacks are not even able to pass with no components.  

 

From: dmmoff...@gmail.com <mailto:dmmoff...@gmail.com>  

Sent: Thursday, August 17, 2023 8:27 PM

To: 'AnimalFarm Microwave Users Group' 

Cc: ch...@go-mtc.com <mailto:ch...@go-mtc.com>  

Subject: RE: [AFMUG] Question for Chuck, and anyone wise who wants to add their 
0.02...

 

Have you played with multi-gig ethernet?

A certain “brand T” has a model of 10gig surge suppressor and it has very few 
components compared to their prior models.  I was wondering if 10G is too 
sensitive to put more components in the line.

-Adam

 

 

From: AF <af-boun...@af.afmug.com <mailto:af-boun...@af.afmug.com> > On Behalf 
Of Chuck McCown via AF
Sent: Thursday, August 17, 2023 9:21 PM
To: AnimalFarm Microwave Users Group <af@af.afmug.com <mailto:af@af.afmug.com> >
Cc: ch...@go-mtc.com <mailto:ch...@go-mtc.com> 
Subject: Re: [AFMUG] Question for Chuck, and anyone wise who wants to add their 
0.02...

 

All CAT6 in our product line are 100% GDT.  Anything that says GIGE has solid 
state and GDT.  I would recommend CAT6 for everything.  

 

 

 

From: Forrest Christian (List Account) 

Sent: Thursday, August 17, 2023 6:22 PM

To: AnimalFarm Microwave Users Group 

Subject: [AFMUG] Question for Chuck, and anyone wise who wants to add their 
0.02...

 

Which of the MTC CAT6 surge suppressors that fit in the APC racks are 
recommended for general use?  

 

I see a Gas discharge and semiconductor diode version on the website.  Guessing 
the GDT version is more robust and less likely to cause errors at the expense 
of reaction time. 

  _____  

-- 
AF mailing list
AF@af.afmug.com <mailto:AF@af.afmug.com> 
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to