http://www.ebay.com/itm/Non-invasive-Split-Core-Current-Transformer-AC-current-sensor-30A-SCT-013-030-/321424072757?pt=LH_DefaultDomain_0&hash=item4ad65e2035
You can get these on Ebay all day long for about $7-$8

-- 
Christopher Tyler 
MTCRE/MTCNA/MTCTCE/MTCWE 
Total Highspeed Internet Services 
417.851.1107

----- Original Message -----
From: "David via Af" <[email protected]>
To: [email protected]
Sent: Wednesday, October 8, 2014 3:34:32 PM
Subject: Re: [AFMUG] packetflux save me

Thats what I thought about doing just didnt want to go to four corners 
of the earth to get parts.
  I may have some old torroids laying around I could just rap some wire 
around and rap the hot leg of each light on there and see if I get any 
where.

On 10/08/2014 09:15 AM, Chuck McCown via Af wrote:
> You can get current transformers that can be applied to the wires 
> without cutting them.  They snap over the wires. Add a rectifier, cap 
> and load resistor and you have a voltage that is proportional to 
> current.  Set some limits in the telemetry and you are monitoring your 
> lights.
> *From:* Tushar Patel via Af <mailto:[email protected]>
> *Sent:* Wednesday, October 08, 2014 6:36 AM
> *To:* [email protected] <mailto:[email protected]>
> *Subject:* Re: [AFMUG] packetflux save me
>
> Forrest,
>
> First search on tower monitor price is close to $940. Do you know the 
> place where you can buy for lot less?
>
> How about following?
>
> http://www.burk.com/Products/Tlm.aspx
>
> Thanks,
>
> Tushar Patel
>
> 512-257-1077
>
> www.westernbroadband.com <http://www.westernbroadband.com/>
>
> *From:*Af [mailto:[email protected]] *On Behalf Of *Forrest 
> Christian (List Account) via Af
> *Sent:* Wednesday, October 08, 2014 2:33 AM
> *To:* af
> *Subject:* Re: [AFMUG] packetflux save me
>
> I was going through my drafts and noticed for some reason the 
> following was still a draft, and hadn't been sent:
>
> Are you saying this is a DC tower lighting system now?  I haven't run 
> across one of those yet.
>
> For AC, I was going to recommend that you look into a tower light 
> monitor with a contact output you could hook into a sitemonitor or 
> similar.   I know people who have used the ones from 
> www.towermonitor.com <http://www.towermonitor.com> with good results.
>
> I'm also looking at building a purpose-built module for the 
> sitemonitor system, but this is a ways down the todo list.
>
> -forrest
>
> On Mon, Sep 15, 2014 at 5:58 AM, David Milholen <[email protected] 
> <mailto:[email protected]>> wrote:
>
> I am going to replace my third elec eye. I am converting the eye to DC 
> with isolation so I dont lose another one
> but I would like to get something simple to monitor the sites lights.
>
> On 9/15/2014 1:18 AM, Forrest Christian (List Account) wrote:
>
>     Hey I was going to reply but I've been traveling and haven't had a
>     chance to access the info I need to reply.
>
>     At this point I'll be back in the office mid week and I'll have
>     some good suggestions for you.
>
>     On Sep 11, 2014 9:34 PM, "David Milholen" <[email protected]
>     <mailto:[email protected]>> wrote:
>
>     Forrest,
>     I was looking over your site trying to find something that would
>     help me to monitor
>     our older tower lighting using incandescent bulbs.
>     I am not sure if the shunts will do the trick because I believe
>     those are for DC current not AC.
>
>     I have some Toroids that may help with the AC current drop across
>     a circuit for indicating its on
>     or off.
>
>     Ill have to pull my old AC circuit analysis book and transducers
>     to see what I have to do to interface it
>     to a site monitor base unit
>
>     -- 
>
> -- 
>

Reply via email to