I ended up ordering a 50/125 MTP cable pre-terminated on one side with 12
LC connections and MTP on the other side.  Then I purchased mtp to 12 LC
adapters.  I just decided forget it and went unarmored in conduit to a 1U
rack mount junction/splice housing on one side and a splice/junction box
outside.  Then I come out of that with patch cables in flex conduit to each
BH.  It worked out perfect but you do not want to know what I paid.  Are
these mtp to 12 LC the 'squids' that you are talking about?

On Sun, Nov 2, 2014 at 8:44 AM, Mike Hammett via Af <af@afmug.com> wrote:

> Has anyone figured out what the "squids" cost that the mobile guys use?
>
>
>
> -----
> Mike Hammett
> Intelligent Computing Solutions
> http://www.ics-il.com
>
> <https://www.facebook.com/ICSIL>
> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb>
> <https://www.linkedin.com/company/intelligent-computing-solutions>
> <https://twitter.com/ICSIL>
>
> ------------------------------
> *From: *"Jeremy via Af" <af@afmug.com>
> *To: *af@afmug.com
> *Sent: *Thursday, September 25, 2014 10:44:26 AM
> *Subject: *[AFMUG] Fiber for tower (revisited)
>
> We are looking to run fiber for all of our licensed backhauls.  I have
> seen Superior Essex armored fiber recommended before.  I had a couple of
> questions.  Do you usually just use two of the 12 fibers and run one cable
> to each backhaul?  Do they make a version with just two pair?  Is there a
> way for me to run the 12 into a box and then splice it out and run 6
> backhauls over it?  Would that be the recommended method?
>
> Then, on to termination....are most of you using the scoring tool and the
> field-installable ends that you squeeze to crimp?  Are these recommended?
> Where is the best place to purchase these ends and tools?  I have attached
> Mike's video of this process (which makes it look very simple btw)
>
> http://youtu.be/rKWLCVgkNtM
>
>

Reply via email to