There isn't anything different between any recent injector daisy chain
wise.  Any straight-through cable on the syncpipe daisy-chain ports, cat5
or flat satin will work - although for longer distances you want CAT5.

The sitemonitor ports can be dasychained with either a straight or reversed
(1-6 to 6-1) 6p6c connector.

I'm assuming you're not asking about power.

-forrest

On Fri, Feb 13, 2015 at 10:28 AM, <bran...@gogebicrange.net> wrote:

> Is there any reason I can’t daisy chain a Gigabit SyncInjector to one of
> the 10/100 SyncInjectors?
>
>
>
> We have a site climb scheduled for Monday and the SyncInjector is in the
> air on the platform of the structure in a box. I don’t know if it’s a Gig
> unit or not but I suspect it is just incase it’s a 10/100 though I want to
> be able to daisy chain to it.
>
>
>
> Also do I use a straight through, cross over, or standard patch cable to
> daisy chaining these units?
>
>
>
>
>
> Thanks,
>
> Brandon Yuchasz
>
>
>