ConnectIt is great, we use the PC30 and PC35 all the time. FYI a PC35 will work with a 2" Heavywall Conduit (Rigid).
Erich Kaiser North Central Tower Consulting er...@northcentraltower.com Office: 630-621-4804 Cell: 630-777-9291 On Fri, Feb 13, 2015 at 8:43 PM, Jeremy <jeremysmi...@gmail.com> wrote: > These are what I've used. They are heavy duty and inexpensive and work > with a large range of pipe sizes. Also, you can replace the bolts with > allthread to build a mount on two sides for clusters (for example, on a > single pole on top of a tower). > > > http://www.ciwireless.com/product/pipe-to-pipe-clamp-set-for-1-12-in-3-12-in-od-pipes-12-in-thick-set-of-2/ > > On Fri, Feb 13, 2015 at 5:49 PM, Jaime Solorza <losguyswirel...@gmail.com> > wrote: > >> Jaime Solorza >> I am doing this universal pipe mount that will allow a larger dish on >> a Rohn type or crappy sheet metal freestanding type. >> >> And doing the larger version of the M-TOW-P >> >> The question is, what size pipe? >> I had initially designed it with 3 inch pipe which is actually 3.5” OD. >> Looking at the pipe chart, 2.5” has an OD of 2.875”. >> >> The smaller pipe would be noticeably lighter to heft. Is that large >> enough to make SAF type mounts happy? >> Or would y’all rather have the larger pipe. >> > >