If I recall this was the model that others were complaining about having strange issues. You may want to go up to the CCR1036-8G-2S+ I know this works with 1Gbps and 10Gbps. Also if you are using POE to power it, you can do the same with the 1036 just open the cover and wire your DC into the 2nd power terminal on the board. Take note the 1036 router draws about 60w.
Erich Kaiser North Central Tower Consulting [email protected] Office: 630-621-4804 Cell: 630-777-9291 On Fri, Feb 20, 2015 at 2:41 AM, Jason McKemie < [email protected]> wrote: > Thanks. The model is CCR1009-8G-1S-1S+. I'm getting some additional > strange behavior. If I disable auto negotiation, the link light comes on > using the SFP+ port. However, the other end (a Cisco Nexus switch) still > shows the interface as down. The standard sfp port claims to get a link > with auto negotiation active, but shows "failed" in the auto negotiation > field. Any way it is configured, this also shows down on the Cisco. I'm > using generic optics right now, but we've gotten the same result using > Cisco optics at both ends. I'll have to try changing the rate select and > rebooting next. > > On Thursday, February 19, 2015, Erich Kaiser <[email protected]> > wrote: > >> [image: Inline image 1] >> >> Try setting it to low and reboot also can try setting speed/duplex >> 1000FDX I have heard what George is talking about as well, what model is it >> that you are using? >> >> Erich Kaiser >> North Central Tower Consulting >> [email protected] >> Office: 630-621-4804 >> Cell: 630-777-9291 >> >> On Thu, Feb 19, 2015 at 5:36 PM, Jason McKemie < >> [email protected]> wrote: >> >>> So disable auto negotiation or just set it to only advertise 1000M full? >>> I only see 10Gbps as being an option when auto negotiation is disabled. >>> >>> On Thursday, February 19, 2015, Erich Kaiser < >>> [email protected]> wrote: >>> >>>> Change speed setting inside interface and reboot the router. >>>> >>>> Erich Kaiser >>>> North Central Tower Consulting >>>> [email protected] >>>> Office: 630-621-4804 >>>> Cell: 630-777-9291 >>>> >>>> On Thu, Feb 19, 2015 at 5:04 PM, Jason McKemie < >>>> [email protected]> wrote: >>>> >>>>> Can anyone think of any reason the same SFP/fiber will link up when >>>>> plugged into a SFP port on a CCR, but will never establish a link when >>>>> plugged into a SFP+ port? >>>> >>>> >>>> >>