Hi, I don't really have enough details to help here yet. We do not see lock-ups...if that is what is happening, I would like to know about it.
Chuck On Wed, Feb 25, 2015 at 10:15 PM, Jaime Solorza <losguyswirel...@gmail.com> wrote: > Sounds like line conditioning might make sense for Air Fibers? > > Jaime Solorza > On Feb 25, 2015 8:19 PM, "Brett A Mansfield" <br...@silverlakeinternet.com> > wrote: > >> Thanks guys. I'll check the voltage and if it's good I won't worry about >> it. I only two links of af24's, so I doubt I'll see this too often. >> >> Thank you, >> Brett A Mansfield >> >> > On Feb 25, 2015, at 7:59 PM, Josh Reynolds <j...@spitwspots.com> wrote: >> > >> > Normally power issues at the site. Voltage sags can do that. >> > >> > We see them do it, but it's very rare. Maybe one every year out of the >> 2 or 3 dozen links we have. >> > >> > -- >> > Josh Reynolds >> > CIO, SPITwSPOTS >> > www.spitwspots.com >> > >> >> On 02/25/2015 03:12 PM, Brett A Mansfield wrote: >> >> Hey whenever have an air five or 20 more lockup on them? My main back >> all just locked up and I can't figure out what happened. A simple power >> cycle resolve the issue. Definitely time to switch to fiber to the tower. >> >> >> >> Thank you, >> >> Brett A Mansfield >> > >> >>