But its so close....

[image: Inline image 1]

Erich Kaiser
North Central Tower
er...@northcentraltower.com
Office: 630-621-4804
Cell: 630-777-9291

On Tue, Mar 10, 2015 at 8:21 PM, George Skorup (Cyber Broadcasting) <
geo...@cbcast.com> wrote:

>  If it's a new-ish unit (RevH) with the black relays, Forrest said they
> are safe for ~60W @ ~48VDC. So if you're asking about running AF power
> through them, yes. Trango licensed, no way.
>
> The older orange Omron relays could do about half the power, so be careful
> with those. I still have quite a few in the field.
>
> On 3/10/2015 7:36 PM, Erich Kaiser wrote:
>
> Forrest can you verify actual allowed amperage and voltage range on the
> Site Monitor 4 Channel Relay?
>
>  Thanks!
>
>
>   Erich Kaiser
> North Central Tower
> er...@northcentraltower.com
> Office: 630-621-4804
> Cell: 630-777-9291
>
>
>

Reply via email to