The number of resets and timing of the resets are configurable.  The
current implementation is on a per module basis but I'm considering the
possibility of per port as well.
On May 10, 2015 5:13 PM, "George Skorup (Cyber Broadcasting)" <
[email protected]> wrote:

>  Awesome. Not sure if my three reset attempts idea makes sense. I'm just
> worried about something like a SS blowing and the PDU sitting there
> resetting the port(s) endlessly. I imagine that's probably not good for the
> electronic breaker thingamajig.
>
> What I have observed with the WB SS's is a nearby lightning strike will
> set them off and the fuse blows. Replace the fuse and everything is usually
> good to go again. If feel better that the SS did something and probably
> saved the radio and/or router/switch port from taking a surge. OTOH, I have
> seen them actually blow completely (saving the gear most of the time) and
> obviously the fuse pops. Get to the site and replace the fuse only to have
> it pop again. That's when I know something else is wrong. :(
>
> On 5/10/2015 5:01 PM, Forrest Christian (List Account) wrote:
>
> All of the modules which have overcurrent trip are going to get this
> functionality.
>
> Timing:
>
> The base unit firmware is getting a (hopefully) final release based on the
> current code.  This code is ready and just needs to be packaged for
> release.  This final release fixes a issue where the base unit Ethernet
> locks up, causing a software deadlock followed by a watchdog reboot.  The
> trigger is bad packets being received, usually as a result of a duplex
> mismatch.
>
> Once that is done, there will be a early adopter chain released for both
> the base unit and expansion modules.  There are added capabilities being
> added to the system which makes the auto reset functionality much easier to
> implement.  For example, the expansion modules will be keeping track of the
> length of time since the last change, which equates to the time since the
> last trip.  This information will be available via the web and via snmp.
> The code we have written for this also includes the auto reset
> functionality.   This actually isn't that far out as most of it is done, we
> just ended up needing to track down this other bug once we were able to
> reproduce it in house, and then backport it to the current release without
> all the new experimental stuff in it.
> On May 10, 2015 12:53 PM, "George Skorup (Cyber Broadcasting)" <
> [email protected]> wrote:
>
>> Question for Forrest. I know it was talked about in the past to have an
>> auto-reset when a port goes into over-current trip for the SyncInjectors.
>> What about the PDU module?
>>
>> I'm working on some stuff that's going to be far away, so the PDU in
>> place of fuse blocks makes total sense, but it would be even more awesome
>> if any tripped outputs could reset themselves after 5-10 seconds. Not sure
>> if this is possible, but maybe like three reset attempts and it gives up
>> would be pretty cool too.
>>
>
>

Reply via email to