Yep.

The recommendation is either to stick with 802.3at or 48v with the old
cambium pinouts, but it doesn't really care.

If you are doing sync over power it cares a bit more.
On Oct 8, 2015 12:16 PM, "Josh Luthman" <j...@imaginenetworksllc.com> wrote:

> Any pair???
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Thu, Oct 8, 2015 at 1:37 PM, Forrest Christian (List Account) <
> li...@packetflux.com> wrote:
>
>> It's in the manual,  but it's actually easy:
>>
>> Put positive on any pair,  and negative on any pair.   48vdc.
>>
>> They recommend any of the standard 802.3at pinnings or the older cambium
>> pinning (positive on brown, negative on blue).
>>
>> Using the pass through for power  will require power on all 4 pairs.
>> On Oct 8, 2015 11:17 AM, "Matt" <matt.mailingli...@gmail.com> wrote:
>>
>>> Does anyone have pinout for 450i gear?
>>>
>>
>

Reply via email to