This is the only AP on the site that is having problems.  All cable runs
are the same (~200ft).

It has also worked for months up until today.  This problem has suffered
the management loss/cold temperature problems as well.

On Wed, Jan 20, 2016 at 2:33 PM, Josh Luthman <j...@imaginenetworksllc.com>
wrote:

> Long power run?  Is it possible you're losing 6v?  The radio stops booting
> at 20v.
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Wed, Jan 20, 2016 at 2:31 PM, Josh Baird <joshba...@gmail.com> wrote:
>
>> Yeah yeah :)
>>
>> So - we moved it from a SyncInjector providing ~26V to a Cambium PoE
>> Injector providing 30V.  It brought it back to life (at least temporarily).
>>
>> On Wed, Jan 20, 2016 at 1:28 PM, Chuck McCown <ch...@wbmfg.com> wrote:
>>
>>> Just teasing...
>>>
>>> *From:* Josh Baird <joshba...@gmail.com>
>>> *Sent:* Wednesday, January 20, 2016 11:23 AM
>>> *To:* af@afmug.com
>>> *Subject:* Re: [AFMUG] To Cambium With Love - Replace the bad ePMP
>>> units.
>>>
>>> There have been some reports that feeding them with 48V fixes *some*
>>> issues.
>>>
>>> On Wed, Jan 20, 2016 at 1:21 PM, Chuck McCown <ch...@wbmfg.com> wrote:
>>>
>>>> Just keep raising the voltage until it starts working dammit!
>>>>
>>>> (That is how the first transatlantic telegraph cable got ruined the
>>>> first week of operation).
>>>>
>>>> *From:* Josh Baird <joshba...@gmail.com>
>>>> *Sent:* Wednesday, January 20, 2016 11:08 AM
>>>> *To:* af@afmug.com
>>>> *Subject:* Re: [AFMUG] To Cambium With Love - Replace the bad ePMP
>>>> units.
>>>>
>>>> Tell me about it.. first decent snow here today, and one of our sites
>>>> is having issues (only the ePMP).  I think we have completely lost one AP.
>>>> We are going to try and feed it 48V (it's currently 24V) and see if that
>>>> brings it back to life.
>>>>
>>>> On Wed, Jan 20, 2016 at 1:00 PM, Tyson Burris @ Internet Communications
>>>> Inc <t...@franklinisp.net> wrote:
>>>>
>>>>> Hello Cambium,
>>>>>
>>>>>
>>>>>
>>>>> At the MidWest-IX launch party last night, several of us Indiana WISPs
>>>>> compared notes on the ‘cold weather’ problems we are seeing with ePMPs.  
>>>>> It
>>>>> was very interesting to learn we are experience identical problems across
>>>>> the spectrum.
>>>>>
>>>>> We all understand this is a DRAM issue with certain units you have
>>>>> identified.  We also understand the firmware RC that has been made
>>>>> available to fix this short term.
>>>>>
>>>>> The bottom line is we are very frustrated and grow tired of dealing
>>>>> with it.
>>>>>
>>>>>
>>>>>
>>>>> Our concern is simple.  If your software fix ‘degrades’ the
>>>>> performance of the product or triggers other issues, as it has been
>>>>> suggested, we would prefer a full recall and replacement program
>>>>> immediately.
>>>>>
>>>>>
>>>>>
>>>>> If the suggestion that the fix will degrade the product performance is
>>>>> inaccurate and not cause other issues, I would like for this to be made
>>>>> public.
>>>>>
>>>>>
>>>>>
>>>>> Thank you,
>>>>>
>>>>>
>>>>>
>>>>> *Tyson Burris, President*
>>>>> *Internet Communications Inc.*
>>>>> *739 Commerce Dr.*
>>>>> *Franklin, IN 46131*
>>>>>
>>>>> *317-738-0320 <317-738-0320> Daytime #*
>>>>> *317-412-1540 <317-412-1540> Cell/Direct #*
>>>>> *Online: **www.surfici.net* <http://www.surfici.net>
>>>>>
>>>>>
>>>>>
>>>>> [image: ICI]
>>>>>
>>>>> *What can ICI do for you?*
>>>>>
>>>>>
>>>>> *Broadband Wireless - PtP/PtMP Solutions - WiMax - Mesh Wifi/Hotzones
>>>>> - IP Security - Fiber - Tower - Infrastructure.*
>>>>>
>>>>> *CONFIDENTIALITY NOTICE: This e-mail is intended for the*
>>>>> *addressee shown. It contains information that is*
>>>>> *confidential and protected from disclosure. Any review,*
>>>>> *dissemination or use of this transmission or its contents by*
>>>>> *unauthorized organizations or individuals is strictly*
>>>>> *prohibited.*
>>>>>
>>>>>
>>>>>
>>>>
>>>>
>>>
>>>
>>
>>
>

Reply via email to